Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
J Orthop Trauma
; 30(1): e7-e11, 2016 Jan.
Article
en En
| MEDLINE
| ID: mdl-26849390
OBJECTIVES: To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate. DESIGN: Retrospective. SETTING: Urban University Level I Trauma Center. PATIENT/PARTICIPANTS: All distal femur fractures (OTA/AO 33-A, B, C) treated from March 2011 through August 2013 were reviewed from our institutional orthopaedic trauma registry. Inclusion criteria were fractures treated with a precontoured distal femoral locking plate and age between 18 and 84. Exclusion criteria were fractures treated with intramedullary nails, arthroplasty, non-precontoured plates, dual plating, or screw fixation alone. The population was divided into 3 groups: less invasive stabilization system (LISS) group (n = 21), treated with LISS plates (Synthes, Paoli, PA); locking condylar plates (LCPs) group (n = 10), treated with LCPs (Synthes, Paoli, PA); and VA group (n = 36), treated with VA distal femoral LCPs (Synthes, Paoli, PA). Average age was 54.6 ± 17.5 years. INTERVENTION: Open reduction internal fixation with one of the above implants was performed. MAIN OUTCOME MEASURES: The patients were followed radiographically for early mechanical implant failure defined as loosening of locking screws, loss of fixation, plate bending, or implant failure. RESULTS: There were no statistically significant differences between groups for age, gender, open fracture, mechanism of injury, or medial comminution. There were 3 failures (14.3%) in group LISS, no failures (0%) in group LCP, and 8 failures (22.2%) in group VA. All 3 failures in group LISS were in A-type fractures (2 periprosthetic) and all failures in group VA were in C-type fractures. When all fractures for all 3 groups were compared for failure rate, there was no statistically significant difference (P = 0.23). However, when only 33-C fractures were compared, there was significantly greater failure rate in the VA group (P = 0.03). The mean time to failure in group VA was 147 days (range 24-401 days) and was significantly earlier (P = 0.034) when compared with group LISS (mean 356 days; range 251-433 days). CONCLUSIONS: Early mechanical failure with the VA distal femoral locking plate is higher than traditional locking plates (LCP and LISS) for OTA/AO 33-C fractures. We caution practicing surgeons against the use of this plate for metaphyseal fragmented distal femur fractures. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Placas Óseas
/
Falla de Equipo
/
Fracturas del Fémur
/
Fijación Interna de Fracturas
Tipo de estudio:
Diagnostic_studies
/
Etiology_studies
/
Observational_studies
/
Prevalence_studies
/
Risk_factors_studies
Límite:
Adolescent
/
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
País/Región como asunto:
America do norte
Idioma:
En
Revista:
J Orthop Trauma
Asunto de la revista:
ORTOPEDIA
/
TRAUMATOLOGIA
Año:
2016
Tipo del documento:
Article
Pais de publicación:
Estados Unidos