Postmarketing Analysis of a Novel, Cordless Ultrasonic Dissector.
Baker, Erin H; Kirks, Russell C; Drummond, Jessica; Naumann, Robert W; Stefanidis, Dimitrios; Swan, Ryan Z; Martinie, John B; Vrochides, Dionisios; Iannitti, David A.
Afiliación
  • Baker EH; Carolinas Medical Center, Charlotte, NC, USA.
  • Kirks RC; Carolinas Medical Center, Charlotte, NC, USA.
  • Drummond J; Carolinas Medical Center, Charlotte, NC, USA.
  • Naumann RW; Carolinas Medical Center, Charlotte, NC, USA.
  • Stefanidis D; Carolinas Medical Center, Charlotte, NC, USA.
  • Swan RZ; Carolinas Medical Center, Charlotte, NC, USA.
  • Martinie JB; Carolinas Medical Center, Charlotte, NC, USA.
  • Vrochides D; Carolinas Medical Center, Charlotte, NC, USA.
  • Iannitti DA; Carolinas Medical Center, Charlotte, NC, USA david.iannitti@carolinashealthcare.org.
Surg Innov ; 23(5): 505-10, 2016 Oct.
Article en En | MEDLINE | ID: mdl-26839213
Introduction Tissue dissection and vessel sealing is performed using a variety of energy sources and surgical devices. We describe the postmarketing analysis of a cordless ultrasonic dissector and vessel sealer in a series of general and gynecological procedures. Methods Patients were prospectively screened and consented for participation. Data collected included demographics, device activations/seals and failures, and patient complications. Surgeons were surveyed following each case. Data was analyzed using standard statistical methods. Results A total of 110 patients were consented and participated in the study. The most frequently performed procedures were bilateral salpingo-oophorectomy (n = 48) and total laparoscopic hysterectomy (n = 36). Mean age was 54.2 years and 79.2% were female. The most frequent number of device activations per case was between 26 and 50 (36.6%). Five failed seals occurred out of 4858 total estimated seals (0.11%). Failed seals were felt to be due to thickened, scarred tissue not amenable to device compression. There were no patient intraoperative complications related to the device itself. Overall, surgeons felt the device was extremely easy to use (97.6%) and no visual obstruction due to steam from the device was encountered (95%). Ninety-five percent of surgeons felt the device was beneficial for soft tissue dissection and vessel sealing. Conclusion Sonicision is safe and effective for use in dissection of soft tissues and vessel sealing in a variety of laparoscopic and open procedures. In this study, there were no complications related to the device itself. The remarkable cordless design of this device enhances its ease of use with overall excellent effectiveness.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vigilancia de Productos Comercializados / Cirugía General / Procedimientos Quirúrgicos Ginecológicos / Instrumentos Quirúrgicos / Ultrasonido / Seguridad del Paciente Tipo de estudio: Observational_studies Límite: Female / Humans / Male Idioma: En Revista: Surg Innov Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vigilancia de Productos Comercializados / Cirugía General / Procedimientos Quirúrgicos Ginecológicos / Instrumentos Quirúrgicos / Ultrasonido / Seguridad del Paciente Tipo de estudio: Observational_studies Límite: Female / Humans / Male Idioma: En Revista: Surg Innov Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos