Your browser doesn't support javascript.
loading
[Evaluation of the Fundamental Performance of 4 Latex Agglutination Reagents to Measure Anti-TP Antibody Concentration and Detailed Investigation of Decision-Mismatched Samples].
Rinsho Byori ; 63(1): 25-31, 2015 Jan.
Article en Ja | MEDLINE | ID: mdl-26524876
Serological diagnosis of syphilis can be made by using the serological test for syphilis (STS) method for detecting a lipid antibody and Treponema pallidum (TP) method for detecting the anti-TP-specific antibody. In STS and TP methods, the basis using latex agglutination reaction has been used in many facilities. However, in latex agglutination, false-positive results due to non-specific reaction have sometimes been obtained in reactions of a routine laboratory test reagent detecting the anti-TP antibody used in our medical laboratory. We evaluated the fundamental performance of 4 reagents to measure anti-TP antibody concentration using latex agglutination: Reagents A, B, C and D produced by SEKISUI MEDICAL, FUJI REBIO, DENKA SEIKEN and SHINO TEST, respectively. We examined the correlations between Reagent A (routine laboratory test reagent) and Reagents B, C, and D in sera from 68 patients, and we performed additional investigation by using a neutralization test, immunochromatography, Western blotting, FTA-ABS (IgG), and STS method by an automatic analyzer for 13 decision-mismatched samples. The fundamental performance of each reagent was as good as that previously reported. Eight of the 13 decision-mismatched samples were false positives due to non-specific reaction of Reagent A. In latex agglutination non-specific reaction is inevitable. However, this study strongly suggests that using a neutralization test and immunochromatography that can be performed quickly is sufficient to verify whether positive reactions are true or false.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Juego de Reactivos para Diagnóstico / Treponema pallidum / Pruebas de Fijación de Látex / Serodiagnóstico de la Sífilis / Sífilis / Anticuerpos Antibacterianos Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Humans Idioma: Ja Revista: Rinsho Byori Año: 2015 Tipo del documento: Article Pais de publicación: Japón
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Juego de Reactivos para Diagnóstico / Treponema pallidum / Pruebas de Fijación de Látex / Serodiagnóstico de la Sífilis / Sífilis / Anticuerpos Antibacterianos Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Humans Idioma: Ja Revista: Rinsho Byori Año: 2015 Tipo del documento: Article Pais de publicación: Japón