Your browser doesn't support javascript.
loading
Arsenic adsorption by iron-aluminium hydroxide coated onto macroporous supports: Insights from X-ray absorption spectroscopy and comparison with granular ferric hydroxides.
Suresh Kumar, Prashanth; Flores, Roxana Quiroga; Sjöstedt, Carin; Önnby, Linda.
Afiliación
  • Suresh Kumar P; Department of Biotechnology, Lund University, SE-221 00 Lund, Sweden.
  • Flores RQ; Department of Biotechnology, Lund University, SE-221 00 Lund, Sweden; Instituto de Investigaciones Fármaco Bioquímicas, Facultad de Ciencias Farmacéuticas y Bioquímicas, Universidad Mayor de San Andrés, La Paz, Bolivia.
  • Sjöstedt C; Department of Chemistry, KTH Royal Institute of Technology, Stockholm, Sweden.
  • Önnby L; Department of Biotechnology, Lund University, SE-221 00 Lund, Sweden. Electronic address: linda.oennby@eawag.ch.
J Hazard Mater ; 302: 166-174, 2016 Jan 25.
Article en En | MEDLINE | ID: mdl-26476303
This paper evaluates the arsenic adsorption characteristics of a macroporous polymer coated with coprecipitated iron-aluminium hydroxides (MHCMP). The MHCMP adsorbent-composite fits best with a pseudo-second order model for As(III) and a pseudo-first order kinetic model for As(V). The MHCMP shows a maximum adsorption capacity of 82.3 and 49.6 mg As/g adsorbent for As(III) and As(V) ions respectively, and adsorption followed the Langmuir model. Extended X-ray absorption fine structure showed that binding of As(III) ions were confirmed to take place on the iron hydroxides coated on the MHCMP, whereas for As(V) ions the binding specificity could not be attributed to one particular metal hydroxide. As(III) formed a bidentate mononuclear complex with Fe sites, whereas As(V) indicated on a bidentate binuclear complex with Al sites or monodentate with Fe sites on the adsorbent. The column experiments were run in a well water spiked with a low concentration of As(III) (100 µg/L) and a commercially available adsorbent (GEH(®)102) based on granular iron-hydroxide was used for comparison. It was found that the MHCMP was able to treat 7 times more volume of well water as compared to GEH(®)102, maintaining the threshold concentration of less than 10 µg As/L, indicating that the MHCMP is a superior adsorbent.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: J Hazard Mater Asunto de la revista: SAUDE AMBIENTAL Año: 2016 Tipo del documento: Article País de afiliación: Suecia Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: J Hazard Mater Asunto de la revista: SAUDE AMBIENTAL Año: 2016 Tipo del documento: Article País de afiliación: Suecia Pais de publicación: Países Bajos