Your browser doesn't support javascript.
loading
Virtual iron concentration imaging based on dual-energy CT for noninvasive quantification and grading of liver iron content: An iron overload rabbit model study.
Luo, Xian Fu; Yang, Yi; Yan, Jing; Xie, Xue Qian; Zhang, Huan; Chai, Wei Min; Wang, Li; Schmidt, Bernhard; Yan, Fu Hua.
Afiliación
  • Luo XF; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197, Ruijin Er Road, Shanghai, 200025, China.
Eur Radiol ; 25(9): 2657-64, 2015 Sep.
Article en En | MEDLINE | ID: mdl-25773943
OBJECTIVES: To assess the accuracy of liver iron content (LIC) quantification and grading ability associated with clinical LIC stratification using virtual iron concentration (VIC) imaging on dual-energy CT (DECT) in an iron overload rabbit model. METHODS: Fifty-one rabbits were prepared as iron-loaded models by intravenous injection of iron dextran. DECT was performed at 80 and 140 kVp. VIC images were derived from an iron-specific algorithm. Postmortem LIC assessments were conducted on an inductively coupled plasma (ICP) spectrometer. Correlation between VIC and LIC was analyzed. VIC were stratified according to the corresponding clinical LIC thresholds of 1.8, 3.2, 7.0, and 15.0 mg Fe/g. Diagnostic performance of stratification was evaluated by receiver operating characteristic analysis. RESULTS: VIC linearly correlated with LIC (r = 0.977, P < 0.01). No significant difference was observed between VIC-derived LICs and ICP (P > 0.05). For the four clinical LIC thresholds, the corresponding cutoff values of VIC were 19.6, 25.3, 36.9, and 61.5 HU, respectively. The highest sensitivity (100%) and specificity (100 %) were achieved at the threshold of 15.0 mg Fe/g. CONCLUSIONS: Virtual iron concentration imaging on DECT showed potential ability to accurately quantify and stratify hepatic iron accumulation in the iron overload rabbit model. KEY POINTS: • Virtual iron concentration (VIC) linearly correlates with liver iron content (LIC). • VIC accurately quantifies LIC. • VIC accurately grades LIC based on clinical LIC stratification.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Sobrecarga de Hierro / Hígado Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: China Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Sobrecarga de Hierro / Hígado Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: China Pais de publicación: Alemania