Your browser doesn't support javascript.
loading
Inter- and intrarater reliability of the Chicago Classification in pediatric high-resolution esophageal manometry recordings.
Singendonk, M M J; Smits, M J; Heijting, I E; van Wijk, M P; Nurko, S; Rosen, R; Weijenborg, P W; Abu-Assi, R; Hoekman, D R; Kuizenga-Wessel, S; Seiboth, G; Benninga, M A; Omari, T I; Kritas, S.
Afiliación
  • Singendonk MM; Department of Pediatric Gastroenterology and Nutrition, Emma Children's Hospital AMC, Amsterdam, The Netherlands; Gastroenterology Unit, Women's and Children's Health Network, North Adelaide, SA, Australia.
Neurogastroenterol Motil ; 27(2): 269-76, 2015 Feb.
Article en En | MEDLINE | ID: mdl-25521418
BACKGROUND: The Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort. METHODS: Thirty pediatric solid state HRM recordings (13M; mean age 12.1 ± 5.1 years) assessing 10 liquid swallows per patient were analyzed twice by 11 raters (six experts, five non-experts). Software-placed anatomical landmarks required manual adjustment or removal. Integrated relaxation pressure (IRP4s), distal contractile integral (DCI), contractile front velocity (CFV), distal latency (DL) and break size (BS), and an overall CC diagnosis were software-generated. In addition, raters provided their subjective CC diagnosis. Reliability was calculated with Cohen's and Fleiss' kappa (κ) and intraclass correlation coefficient (ICC). KEY RESULTS: Intra- and interrater reliability of software-generated CC diagnosis after manual adjustment of landmarks was substantial (mean κ = 0.69 and 0.77 respectively) and moderate-substantial for subjective CC diagnosis (mean κ = 0.70 and 0.58 respectively). Reliability of both software-generated and subjective diagnosis of normal motility was high (κ = 0.81 and κ = 0.79). Intra- and interrater reliability were excellent for IRP4s, DCI, and BS. Experts had higher interrater reliability than non-experts for DL (ICC = 0.65 vs ICC = 0.36 respectively) and the software-generated diagnosis diffuse esophageal spasm (DES, κ = 0.64 vs κ = 0.30). Among experts, the reliability for the subjective diagnosis of achalasia and esophageal gastric junction outflow obstruction was moderate-substantial (κ = 0.45-0.82). CONCLUSIONS & INFERENCES: Inter- and intrarater reliability of software-based CC diagnosis of pediatric HRM recordings was high overall. However, experience was a factor influencing the diagnosis of some motility disorders, particularly DES and achalasia.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Interpretación de Imagen Asistida por Computador / Trastornos de la Motilidad Esofágica / Manometría Tipo de estudio: Etiology_studies / Guideline / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adolescent / Child / Humans Idioma: En Revista: Neurogastroenterol Motil Asunto de la revista: GASTROENTEROLOGIA / NEUROLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Interpretación de Imagen Asistida por Computador / Trastornos de la Motilidad Esofágica / Manometría Tipo de estudio: Etiology_studies / Guideline / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adolescent / Child / Humans Idioma: En Revista: Neurogastroenterol Motil Asunto de la revista: GASTROENTEROLOGIA / NEUROLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Reino Unido