Trans-subscapularis portal versus low-anterior portal for low anchor placement on the inferior glenoid fossa: a cadaveric shoulder study with computed tomographic analysis.
Arthroscopy
; 31(2): 209-14, 2015 Feb.
Article
en En
| MEDLINE
| ID: mdl-25281478
PURPOSE: The purpose of this study was to evaluate the accuracy of inserting a glenoid anchor at the 5:30 clockface position using a trans-subscapularis (TSS) portal versus a low anterior (LA) portal. METHODS: Five surgeons (T.D., J.C., C.V., D.J.O-H., J.S.T.) placed a single anchor in 20 fresh-frozen cadaveric shoulders. In each of 2 shoulders, surgeons used an LA portal to insert the anchor, whereas in 2 shoulders a TSS portal was used. Surgeons were directed to place the anchor at the 5:30 position at an angle 45° to the glenoid surface (axial plane) and passing perpendicular to the glenoid rim in the coronal plane. Shoulders were then dissected and computed tomographic (CT) scans obtained. Anchor position relative to the clockface was documented by 2 blinded assessors, as was the angle of insertion in the axial and coronal planes. Statistical significance was calculated with a Student t test for paired samples (confidence interval [CI], 95%; significance, P < .05). RESULTS: The average deviation from the 5:30 position was 48 minutes (standard deviation [SD], 31 minutes) for the LA portal (average position, 4:42 o'clock) versus 28.5 minutes (SD, 19 minutes) for the TSS group (average position, 5:02 o'clock) (P = .15). The average angle of anchor insertion in the axial plane was 67.2° (SD, 19°) for the LA portal versus 62.8° (SD, 14°) for the TSS portal (P = .49), whereas the average angle of insertion in the coronal plane was 31.3° (SD, 14°) of inferior angulation in the LA group and 14.3° (SD, 8°) of inferior angulation in the TSS group (P = .009). Of the anchors inserted, 9 of 20 (45%) showed evidence of far-cortical perforation. No difference in cortical perforation was seen between the 2 portals, with perforation more likely with anchors inserted greater than 45° in the axial plane (8 of 20) than with those inserted less than 45° (1 of 20) (P = .02). CONCLUSIONS: The use of a TSS portal improves the angle of approach to the inferior glenoid rim in comparison with an LA portal, reducing the acuity of the angle of insertion in the coronal plane. CLINICAL RELEVANCE: The TSS portal is an option for surgeons performing arthroscopic Bankart repair using anchors low on the glenoid rim.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Artroscopía
/
Articulación del Hombro
/
Anclas para Sutura
/
Cavidad Glenoidea
Límite:
Humans
Idioma:
En
Revista:
Arthroscopy
Asunto de la revista:
ORTOPEDIA
Año:
2015
Tipo del documento:
Article
Pais de publicación:
Estados Unidos