Your browser doesn't support javascript.
loading
Ordinary kriging approach to predicting long-term particulate matter concentrations in seven major Korean cities.
Kim, Sun-Young; Yi, Seon-Ju; Eum, Young Seob; Choi, Hae-Jin; Shin, Hyesop; Ryou, Hyoung Gon; Kim, Ho.
Afiliación
  • Kim SY; Institute of Health and Environment, Seoul National University, Seoul, Korea.
  • Yi SJ; Department of Epidemiology and Biostatistics, Graduate School of Public Health, Seoul National University, Seoul, Korea.
  • Eum YS; Department of Geography, Seoul National University, Seoul, Korea.
  • Choi HJ; Department of Epidemiology and Biostatistics, Graduate School of Public Health, Seoul National University, Seoul, Korea.
  • Shin H; Geo Consulting & Information, Daegu, Korea.
  • Ryou HG; Institute of Health and Environment, Seoul National University, Seoul, Korea.
  • Kim H; Department of Epidemiology and Biostatistics, Graduate School of Public Health, Seoul National University, Seoul, Korea.
Environ Health Toxicol ; 29: e2014012, 2014.
Article en En | MEDLINE | ID: mdl-25262773
OBJECTIVES: Cohort studies of associations between air pollution and health have used exposure prediction approaches to estimate individual-level concentrations. A common prediction method used in Korean cohort studies is ordinary kriging. In this study, performance of ordinary kriging models for long-term particulate matter less than or equal to 10 µm in diameter (PM10) concentrations in seven major Korean cities was investigated with a focus on spatial prediction ability. METHODS: We obtained hourly PM10 data for 2010 at 226 urban-ambient monitoring sites in South Korea and computed annual average PM10 concentrations at each site. Given the annual averages, we developed ordinary kriging prediction models for each of the seven major cities and for the entire country by using an exponential covariance reference model and a maximum likelihood estimation method. For model evaluation, cross-validation was performed and mean square error and R-squared (R(2)) statistics were computed. RESULTS: Mean annual average PM10 concentrations in the seven major cities ranged between 45.5 and 66.0 µg/m(3) (standard deviation=2.40 and 9.51 µg/m(3), respectively). Cross-validated R(2) values in Seoul and Busan were 0.31 and 0.23, respectively, whereas the other five cities had R(2) values of zero. The national model produced a higher crossvalidated R(2) (0.36) than those for the city-specific models. CONCLUSIONS: In general, the ordinary kriging models performed poorly for the seven major cities and the entire country of South Korea, but the model performance was better in the national model. To improve model performance, future studies should examine different prediction approaches that incorporate PM10 source characteristics.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Environ Health Toxicol Año: 2014 Tipo del documento: Article Pais de publicación: Corea del Sur

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Environ Health Toxicol Año: 2014 Tipo del documento: Article Pais de publicación: Corea del Sur