Your browser doesn't support javascript.
loading
Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?
Kampf, Günter; Fliss, Patricia M; Martiny, Heike.
Afiliación
  • Kampf G; Günter Kampf, Patricia M Fliss, Bode Science Center, Bode Chemie GmbH, 22525 Hamburg, Germany.
  • Fliss PM; Günter Kampf, Patricia M Fliss, Bode Science Center, Bode Chemie GmbH, 22525 Hamburg, Germany.
  • Martiny H; Günter Kampf, Patricia M Fliss, Bode Science Center, Bode Chemie GmbH, 22525 Hamburg, Germany.
World J Gastrointest Endosc ; 6(9): 390-406, 2014 Sep 16.
Article en En | MEDLINE | ID: mdl-25228941
The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: World J Gastrointest Endosc Año: 2014 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: World J Gastrointest Endosc Año: 2014 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos