Your browser doesn't support javascript.
loading
An interchangeable scanning Hall probe/scanning SQUID microscope.
Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M J; Ling, D C; Chi, C C; Chen, Jeng-Chung.
Afiliación
  • Tang CC; Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan.
  • Lin HT; Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan.
  • Wu SL; Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan.
  • Chen TJ; Institute of Astronomy and Astrophysics, Academia Sinica, Taipei 10617, Taiwan.
  • Wang MJ; Institute of Astronomy and Astrophysics, Academia Sinica, Taipei 10617, Taiwan.
  • Ling DC; Department of Physics, Tamkang University, Tamsui Dist., New Taipei City 25137, Taiwan.
  • Chi CC; Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan.
  • Chen JC; Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan.
Rev Sci Instrum ; 85(8): 083707, 2014 Aug.
Article en En | MEDLINE | ID: mdl-25173276
We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 µm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10(-7) T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La(2/3)Ca(1/3)MnO3 thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2014 Tipo del documento: Article País de afiliación: Taiwán Pais de publicación: Estados Unidos