Relationship between HgbA1c and myocardial blood flow reserve in patients with type 2 diabetes mellitus: noninvasive assessment using real-time myocardial perfusion echocardiography.
Huang, Runqing; Abdelmoneim, Sahar S; Nhola, Lara F; Mulvagh, Sharon L.
Afiliación
  • Huang R; Mayo Clinic Cardiovascular Ultrasound and Hemodynamic Laboratory, Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA ; Division of Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wu
  • Abdelmoneim SS; Mayo Clinic Cardiovascular Ultrasound and Hemodynamic Laboratory, Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA ; Division of Cardiovascular Medicine, Assiut University, Assiut 71515, Egypt.
  • Nhola LF; Mayo Clinic Cardiovascular Ultrasound and Hemodynamic Laboratory, Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
  • Mulvagh SL; Mayo Clinic Cardiovascular Ultrasound and Hemodynamic Laboratory, Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
J Diabetes Res ; 2014: 243518, 2014.
Article en En | MEDLINE | ID: mdl-25097860
To study the relationship between glycosylated hemoglobin (HgbA1c) and myocardial perfusion in type 2 diabetes mellitus (T2DM) patients, we prospectively enrolled 24 patients with known or suspected coronary artery disease (CAD) who underwent adenosine stress by real-time myocardial perfusion echocardiography (RTMPE). HgbA1c was measured at time of RTMPE. Microbubble velocity (ß min(-1)), myocardial blood flow (MBF, mL/min/g), and myocardial blood flow reserve (MBFR) were quantified. Quantitative MCE analysis was feasible in all patients (272/384 segments, 71%). Those with HgbA1c > 7.1% had significantly lower ßreserve and MBFR than those with HgbA1c ≤ 7.1% (P < 0.05). In patients with suspected CAD, there was a significant inverse correlation between MBFR and HgbA1c (r = -0.279, P = 0.01); however, in those with known CAD, this relationship was not significant (r = -0.117, P = 0.129). Using a MBFR cutoff value > 2 as normal, HgbA1c > 7.1% significantly increased the risk for abnormal MBFR, (adjusted odds ratio: 1.92, 95% CI: 1.12-3.35, P = 0.02). Optimal glycemic control is associated with preservation of MBFR as determined by RTMPE, in T2DM patients at risk for CAD.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Hemoglobina Glucada / Ecocardiografía de Estrés / Diabetes Mellitus Tipo 2 / Angiopatías Diabéticas / Reserva del Flujo Fraccional Miocárdico / Imagen de Perfusión Miocárdica Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Diabetes Res Año: 2014 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Hemoglobina Glucada / Ecocardiografía de Estrés / Diabetes Mellitus Tipo 2 / Angiopatías Diabéticas / Reserva del Flujo Fraccional Miocárdico / Imagen de Perfusión Miocárdica Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Diabetes Res Año: 2014 Tipo del documento: Article Pais de publicación: Reino Unido