Trocar-sharpened needles for image-guided prostate biopsy improve sample quality and performance: first clinical results.
Simpfendörfer, Tobias; Kuru, Timur H; Steinemann, Sarah; Bergsträsser, Claudia; Block, Svenja; Roth, Wilfried; Roethke, Matthias C; Hohenfellner, Markus; Hadaschik, Boris A.
Afiliación
  • Simpfendörfer T; 1 Department of Urology, University Hospital Heidelberg , Heidelberg, Germany .
J Endourol ; 28(11): 1384-8, 2014 Nov.
Article en En | MEDLINE | ID: mdl-24935738
OBJECTIVE: To show the benefit of trocar-sharpened needles for image-guided prostate biopsy compared with standard bevelled needles in patients. MATERIALS AND METHODS: Twenty-four men underwent magnetic resonance imaging-targeted fusion-guided transperineal saturation prostate biopsy, each with half standard bevelled and half trocar-sharpened needles. All taken biopsies were scored (1=worse to 5=best) by one urologist for the following criteria. (1) Accuracy of matching between planned and performed biopsy. (2) Histologic quality of the sample. (3) Elegance, which is the easiness to take the biopsy in proper time, planned position, and best histologic quality. Afterward, the histologic sample quality was evaluated by a blinded pathologist. To show a possible training effect, blinded untrained junior residents performed biopsies in four men (103 cores). RESULTS: Overall, 600 single biopsies were analyzed. The trocar-sharpened needles demonstrated a significantly (p<0.05) better scoring for accuracy and elegance rated by the urologist. The histologic quality scored by the pathologist was superior. Moreover, significantly lower target errors with trocar-sharpened needles were achieved by untrained residents, but not by the experienced user. CONCLUSION: Using trocar-sharpened needles helps urologists to perform targeted prostate biopsy more elegantly and accurately. In addition, the histopathologic sample quality was superior, which may directly improve diagnostic certainty. There is an undeniable training effect in image-guided biopsy and unexperienced users can significantly reduce target errors with trocar-sharpened needles.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Biopsia con Aguja / Biopsia Guiada por Imagen Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: J Endourol Asunto de la revista: UROLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Biopsia con Aguja / Biopsia Guiada por Imagen Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: J Endourol Asunto de la revista: UROLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos