Prevalence and test characteristics of national health safety network ventilator-associated events.
Lilly, Craig M; Landry, Karen E; Sood, Rahul N; Dunnington, Cheryl H; Ellison, Richard T; Bagley, Peter H; Baker, Stephen P; Cody, Shawn; Irwin, Richard S.
Afiliación
  • Lilly CM; 1Department of Medicine, University of Massachusetts Medical School, Worcester, MA. 2Department of Anesthesiology and Surgery, University of Massachusetts Medical School, Worcester, MA. 3Clinical and Population Health Research Program, University of Massachusetts Medical School, Worcester, MA. 4Graduate School of Biomedical Sciences, University of Massachusetts Medical School, Worcester, MA. 5Department of Critical Care Operations, UMass Memorial Health Care, Worcester, MA. 6Department of Nursin
Crit Care Med ; 42(9): 2019-28, 2014 Sep.
Article en En | MEDLINE | ID: mdl-24810522
OBJECTIVES: The primary aim of the study was to measure the test characteristics of the National Health Safety Network ventilator-associated event/ventilator-associated condition constructs for detecting ventilator-associated pneumonia. Its secondary aims were to report the clinical features of patients with National Health Safety Network ventilator-associated event/ventilator-associated condition, measure costs of surveillance, and its susceptibility to manipulation. DESIGN: Prospective cohort study. SETTING: Two inpatient campuses of an academic medical center. PATIENTS: Eight thousand four hundred eight mechanically ventilated adults discharged from an ICU. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs detected less than a third of ventilator-associated pneumonia cases with a sensitivity of 0.325 and a positive predictive value of 0.07. Most National Health Safety Network ventilator-associated event/ventilator-associated condition cases (93%) did not have ventilator-associated pneumonia or other hospital-acquired complications; 71% met the definition for acute respiratory distress syndrome. Similarly, most patients with National Health Safety Network probable ventilator-associated pneumonia did not have ventilator-associated pneumonia because radiographic criteria were not met. National Health Safety Network ventilator-associated event/ventilator-associated condition rates were reduced 93% by an unsophisticated manipulation of ventilator management protocols. CONCLUSIONS: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs failed to detect many patients who had ventilator-associated pneumonia, detected many cases that did not have a hospital complication, and were susceptible to manipulation. National Health Safety Network ventilator-associated event/ventilator-associated condition surveillance did not perform as well as ventilator-associated pneumonia surveillance and had several undesirable characteristics.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neumonía Asociada al Ventilador / Vigilancia en Salud Pública / Unidades de Cuidados Intensivos Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Med Año: 2014 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neumonía Asociada al Ventilador / Vigilancia en Salud Pública / Unidades de Cuidados Intensivos Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Med Año: 2014 Tipo del documento: Article Pais de publicación: Estados Unidos