Prevalence and test characteristics of national health safety network ventilator-associated events.
Crit Care Med
; 42(9): 2019-28, 2014 Sep.
Article
en En
| MEDLINE
| ID: mdl-24810522
OBJECTIVES: The primary aim of the study was to measure the test characteristics of the National Health Safety Network ventilator-associated event/ventilator-associated condition constructs for detecting ventilator-associated pneumonia. Its secondary aims were to report the clinical features of patients with National Health Safety Network ventilator-associated event/ventilator-associated condition, measure costs of surveillance, and its susceptibility to manipulation. DESIGN: Prospective cohort study. SETTING: Two inpatient campuses of an academic medical center. PATIENTS: Eight thousand four hundred eight mechanically ventilated adults discharged from an ICU. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs detected less than a third of ventilator-associated pneumonia cases with a sensitivity of 0.325 and a positive predictive value of 0.07. Most National Health Safety Network ventilator-associated event/ventilator-associated condition cases (93%) did not have ventilator-associated pneumonia or other hospital-acquired complications; 71% met the definition for acute respiratory distress syndrome. Similarly, most patients with National Health Safety Network probable ventilator-associated pneumonia did not have ventilator-associated pneumonia because radiographic criteria were not met. National Health Safety Network ventilator-associated event/ventilator-associated condition rates were reduced 93% by an unsophisticated manipulation of ventilator management protocols. CONCLUSIONS: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs failed to detect many patients who had ventilator-associated pneumonia, detected many cases that did not have a hospital complication, and were susceptible to manipulation. National Health Safety Network ventilator-associated event/ventilator-associated condition surveillance did not perform as well as ventilator-associated pneumonia surveillance and had several undesirable characteristics.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Neumonía Asociada al Ventilador
/
Vigilancia en Salud Pública
/
Unidades de Cuidados Intensivos
Tipo de estudio:
Etiology_studies
/
Guideline
/
Observational_studies
/
Prevalence_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Crit Care Med
Año:
2014
Tipo del documento:
Article
Pais de publicación:
Estados Unidos