Your browser doesn't support javascript.
loading
Evaluation of lightweight wheelchairs using ANSI/RESNA testing standards.
Gebrosky, Benjamin; Pearlman, Jonathan; Cooper, Rory A; Cooper, Rosemarie; Kelleher, Annmarie.
Afiliación
  • Gebrosky B; Human Engineering Research Laboratories, Department of Veterans Affairs (VA), Rehabilitation Research and Development Service, VA Pittsburgh Healthcare System, Pittsburgh, PA.
J Rehabil Res Dev ; 50(10): 1373-89, 2013.
Article en En | MEDLINE | ID: mdl-24699973
Lightweight wheelchairs are characterized by their low cost and limited range of adjustment. Our study evaluated three different folding lightweight wheelchair models using the American National Standards Institute/Rehabilitation Engineering Society of North America (ANSI/RESNA) standards to see whether quality had improved since the previous data were reported. On the basis of reports of increasing breakdown rates in the community, we hypothesized that the quality of these wheelchairs had declined. Seven of the nine wheelchairs tested failed to pass the multidrum test durability requirements. An average of 194,502 +/- 172,668 equivalent cycles was completed, which is similar to the previous test results and far below the 400,000 minimum required to pass the ANSI/RESNA requirements. This was also significantly worse than the test results for aluminum ultralight folding wheelchairs. Overall, our results uncovered some disturbing issues with these wheelchairs and suggest that manufacturers should put more effort into this category to improve quality. To improve the durability of lightweight wheelchairs, we suggested that stronger regulations be developed that require wheelchairs to be tested by independent and certified test laboratories. We also proposed a wheelchair rating system based on the National Highway Transportation Safety Administration vehicle crash ratings to assist clinicians and end users when comparing the durability of different wheelchairs.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Silla de Ruedas / Análisis de Falla de Equipo Tipo de estudio: Evaluation_studies / Guideline / Prognostic_studies Límite: Humans Idioma: En Revista: J Rehabil Res Dev Asunto de la revista: ENGENHARIA BIOMEDICA / REABILITACAO Año: 2013 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Silla de Ruedas / Análisis de Falla de Equipo Tipo de estudio: Evaluation_studies / Guideline / Prognostic_studies Límite: Humans Idioma: En Revista: J Rehabil Res Dev Asunto de la revista: ENGENHARIA BIOMEDICA / REABILITACAO Año: 2013 Tipo del documento: Article Pais de publicación: Estados Unidos