Corneal reshaping and wavefront aberrations during overnight orthokeratology.
Lian, Yan; Shen, Meixiao; Huang, Shenghai; Yuan, Yimin; Wang, Yaozeng; Zhu, Dexi; Jiang, Jun; Mao, Xinjie; Wang, Jianhua; Lu, Fan.
Afiliación
  • Lian Y; School of Ophthalmology and Optometry (Y.L., M.S., S.H., Y.Y., Y.W., D.Z., J.J., X.M., and F.L.), Wenzhou Medical University, Wenzhou, Zhejiang, China; and Department of Ophthalmology (J.W.), Bascom Palmer Eye Institute, University of Miami, Miami, FL.
Eye Contact Lens ; 40(3): 161-8, 2014 May.
Article en En | MEDLINE | ID: mdl-24681612
PURPOSE: To investigate changes of corneal thickness at the vertical and horizontal meridians and of wavefront aberrations (WA) over a 30-day period of overnight myopia orthokeratology (OK) lens wear. METHODS: Sixteen subjects (11 women, 5 men, 26.3±3.2 years) were enrolled and fitted for OK lenses. Long scan depth optical coherence tomography was used to measure corneal thickness profiles at both horizontal and vertical meridians at baseline and on days 1, 7, and 30 days. Corneal and ocular WA of a 6-mm pupil were measured and the root-mean-square (RMS) of the astigmatism, coma, spherical aberration (SA), and total higher-order aberrations (HOAs) were determined. RESULTS: During the 30-day period, the central cornea thinned in the horizontal and vertical meridians, whereas corneal thickening occurred in the temporal, nasal, and inferior mid-peripheries. In contrast, the cornea thinned in the mid-peripheral superior. There were significant increases in RMS for astigmatism, SA, coma, and positive horizontal coma during the study period. After OK, there were significant positive correlations between the midperipheral-central thickness change difference and the changes in corneal and ocular RMS of total HOAs and SA (r range: 0.281 to 0.492, P<0.05). Only the change of corneal coma RMS was correlated with midperipheral-central thickness change difference (r=0.270, P<0.05). The change in corneal horizontal coma was correlated with the temporal-nasal thickness change difference (r=-0.289, P<0.05). CONCLUSIONS: Overnight OK caused unique changes in corneal thickness profiles at the vertical and horizontal meridians and increased corneal and ocular HOAs related to corneal reshaping.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procedimientos de Ortoqueratología / Aberración de Frente de Onda Corneal / Miopía Límite: Adult / Female / Humans / Male Idioma: En Revista: Eye Contact Lens Asunto de la revista: OFTALMOLOGIA Año: 2014 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procedimientos de Ortoqueratología / Aberración de Frente de Onda Corneal / Miopía Límite: Adult / Female / Humans / Male Idioma: En Revista: Eye Contact Lens Asunto de la revista: OFTALMOLOGIA Año: 2014 Tipo del documento: Article Pais de publicación: Estados Unidos