Monte Carlo Simulation of Siemens ONCOR Linear Accelerator with BEAMnrc and DOSXYZnrc Code.
Jabbari, Keyvan; Anvar, Hossein Saberi; Tavakoli, Mohammad Bagher; Amouheidari, Alireza.
Afiliación
  • Jabbari K; Department of Medical Physics and Engineering, School of Medicine, Medical Image & Signal Processing Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Anvar HS; Department of Medical Physics and Engineering, School of Medicine, Medical Image & Signal Processing Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Tavakoli MB; Department of Medical Physics and Engineering, School of Medicine, Medical Image & Signal Processing Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Amouheidari A; Department of Radiation-Oncology, Isfahan Milad Hospital, Isfahan, Iran.
J Med Signals Sens ; 3(3): 172-9, 2013 Jul.
Article en En | MEDLINE | ID: mdl-24672765
The Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. In this work, a Monte Carlo modeling of the Siemens ONCOR linear accelerator in 6 MV and 18 MV beams was performed. The results of simulation were validated by measurements in water by ionization chamber and extended dose range (EDR2) film in solid water. The linac's X-ray particular are so sensitive to the properties of primary electron beam. Square field size of 10 cm × 10 cm produced by the jaws was compared with ionization chamber and film measurements. Head simulation was performed with BEAMnrc and dose calculation with DOSXYZnrc for film measurements and 3ddose file produced by DOSXYZnrc analyzed used homemade MATLAB program. At 6 MV, the agreement between dose calculated by Monte Carlo modeling and direct measurement was obtained to the least restrictive of 1%, even in the build-up region. At 18 MV, the agreement was obtained 1%, except for in the build-up region. In the build-up region, the difference was 1% at 6 MV and 2% at 18 MV. The mean difference between measurements and Monte Carlo simulation is very small in both of ONCOR X-ray energy. The results are highly accurate and can be used for many applications such as patient dose calculation in treatment planning and in studies that model this linac with small field size like intensity-modulated radiation therapy technique.