Your browser doesn't support javascript.
loading
Highly efficient beamline and spectrometer for inelastic soft X-ray scattering at high resolution.
Lai, C H; Fung, H S; Wu, W B; Huang, H Y; Fu, H W; Lin, S W; Huang, S W; Chiu, C C; Wang, D J; Huang, L J; Tseng, T C; Chung, S C; Chen, C T; Huang, D J.
Afiliación
  • Lai CH; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Fung HS; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Wu WB; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Huang HY; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Fu HW; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Lin SW; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Huang SW; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Chiu CC; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Wang DJ; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Huang LJ; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Tseng TC; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Chung SC; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Chen CT; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
  • Huang DJ; National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
J Synchrotron Radiat ; 21(Pt 2): 325-32, 2014 Mar.
Article en En | MEDLINE | ID: mdl-24562553
The design, construction and commissioning of a beamline and spectrometer for inelastic soft X-ray scattering at high resolution in a highly efficient system are presented. Based on the energy-compensation principle of grating dispersion, the design of the monochromator-spectrometer system greatly enhances the efficiency of measurement of inelastic soft X-rays scattering. Comprising two bendable gratings, the set-up effectively diminishes the defocus and coma aberrations. At commissioning, this system showed results of spin-flip, d-d and charge-transfer excitations of NiO. These results are consistent with published results but exhibit improved spectral resolution and increased efficiency of measurement. The best energy resolution of the set-up in terms of full width at half-maximum is 108 meV at an incident photon energy tuned about the Ni L3-edge.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Synchrotron Radiat Asunto de la revista: RADIOLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Taiwán Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Synchrotron Radiat Asunto de la revista: RADIOLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Taiwán Pais de publicación: Estados Unidos