Your browser doesn't support javascript.
loading
Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography.
Kirisli, H A; Schaap, M; Metz, C T; Dharampal, A S; Meijboom, W B; Papadopoulou, S L; Dedic, A; Nieman, K; de Graaf, M A; Meijs, M F L; Cramer, M J; Broersen, A; Cetin, S; Eslami, A; Flórez-Valencia, L; Lor, K L; Matuszewski, B; Melki, I; Mohr, B; Oksüz, I; Shahzad, R; Wang, C; Kitslaar, P H; Unal, G; Katouzian, A; Örkisz, M; Chen, C M; Precioso, F; Najman, L; Masood, S; Ünay, D; van Vliet, L; Moreno, R; Goldenberg, R; Vuçini, E; Krestin, G P; Niessen, W J; van Walsum, T.
Afiliación
  • Kirisli HA; Biomedical Imaging Group Rotterdam, Dept.of Radiology and Med. Informatics, Erasmus MC, Rotterdam, The Netherlands; Div. of Image Processing, Dept.of Radiology, Leiden UMC, Leiden, The Netherlands.
Med Image Anal ; 17(8): 859-76, 2013 Dec.
Article en En | MEDLINE | ID: mdl-23837963
Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Reconocimiento de Normas Patrones Automatizadas / Interpretación de Imagen Radiográfica Asistida por Computador / Tomografía Computarizada por Rayos X / Angiografía Coronaria / Estenosis Coronaria Tipo de estudio: Clinical_trials / Diagnostic_studies / Guideline Límite: Adult / Aged / Aged80 / Humans / Middle aged País/Región como asunto: Europa Idioma: En Revista: Med Image Anal Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2013 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Reconocimiento de Normas Patrones Automatizadas / Interpretación de Imagen Radiográfica Asistida por Computador / Tomografía Computarizada por Rayos X / Angiografía Coronaria / Estenosis Coronaria Tipo de estudio: Clinical_trials / Diagnostic_studies / Guideline Límite: Adult / Aged / Aged80 / Humans / Middle aged País/Región como asunto: Europa Idioma: En Revista: Med Image Anal Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2013 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Países Bajos