Your browser doesn't support javascript.
loading
Does the new Helix 3D hip joint improve walking of hip disarticulated amputees?
Gailledrat, E; Moineau, B; Seetha, V; DeAngelis, M P; Saurel, B; Chabloz, P; Nougier, V; Pérennou, D.
Afiliación
  • Gailledrat E; Department of Physical Medicine and Rehabilitation, Grenoble University Hospital, Institute of Rehabilitation, avenue de Kimberley, CS 90338, BP, 38434 Echirolles cedex, France. EGailledrat@chu-grenoble.fr
Ann Phys Rehabil Med ; 56(5): 411-8, 2013 Jul.
Article en En | MEDLINE | ID: mdl-23830863
PURPOSE: Testing the new hip joint Helix3D efficiency through clinical data and walking parameters. METHOD: Three young hip-disarticulated patients (P1, P2 and P3) were assessed both with their previous prosthesis at first day, then four days and six months after being trained with a new prosthesis equipped with the Helix3D hip joint. Assessments comprised a satisfaction questionnaire, a two-minute walk test and a recording of main spatiotemporal gait parameters RESULTS: After four days with the Helix3D, the satisfaction for the prosthesis was improved for P1, unchanged for P2 and reduced for P3. Distance walked during two minutes increased for P1, unchanged for P2 and slightly improved for P3. Gait pattern was improved in P1, only. P1 abandoned the Helix3D at six months due to an ischiatic wound. P2 and P3 chose not to use the Helix at the end of the four days training period because they could not adapt to the Helix3D characteristics (hydraulic control of hip extension and assistance to hip flexion) and because they did not gain enough benefits. Despite much effort to adjust the prosthesis, the three patients definitively abandoned the Helix3D because of comfort problems, and decided to walk with their previous prosthesis equipped with a monocentric hip joint or even with crutches only. CONCLUSION: The Helix3D hip joint may need further developments to get clinically relevant for hip-disarticulated amputees who may also need a long training period to adapt to its technical characteristics.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Caminata / Satisfacción del Paciente / Desarticulación / Prótesis de Cadera Límite: Adult / Female / Humans / Male Idioma: En Revista: Ann Phys Rehabil Med Asunto de la revista: MEDICINA FISICA / REABILITACAO Año: 2013 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Caminata / Satisfacción del Paciente / Desarticulación / Prótesis de Cadera Límite: Adult / Female / Humans / Male Idioma: En Revista: Ann Phys Rehabil Med Asunto de la revista: MEDICINA FISICA / REABILITACAO Año: 2013 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Países Bajos