Communication latencies of Apple push notification messages relevant for delivery of time-critical information to anesthesia providers.
Anesth Analg
; 117(2): 398-404, 2013 Aug.
Article
en En
| MEDLINE
| ID: mdl-23757478
BACKGROUND: Tablet computers and smart phones have gained popularity in anesthesia departments for educational and patient care purposes. VigiVU(™) is an iOS application developed at Vanderbilt University for remote viewing of perioperative information, including text message notifications delivered via the Apple Push Notification (APN) service. In this study, we assessed the reliability of the APN service. METHODS: Custom software was written to send a message every minute to iOS devices (iPad(®), iPod Touch(®), and iPhone(®)) via wireless local area network (WLAN) and cellular pathways 24 hours a day over a 4-month period. Transmission and receipt times were recorded and batched by days, with latencies calculated as their differences. The mean, SEM, and the exact 95% upper confidence limits for the percent of days with ≥1 prolonged (>100 seconds) latency were calculated. Acceptable performance was defined as mean latency <30 seconds and ≤0.5% of latencies >100 seconds. Testing conditions included fixed locations of devices in high signal strength locations. RESULTS: Mean latencies were <1 second for iPad and iPod devices (WLAN), and <4 seconds for iPhone (cellular). Among >173,000 iPad and iPod latencies, none were >100 seconds. For iPhone latencies, 0.03% ± 0.01% were >100 seconds. The 95% upper confidence limits of days with ≥1 prolonged latency were 42% (iPhone) and 5% to 8% (iPad, iPod). CONCLUSIONS: The APN service was reliable for all studied devices over WLAN and cellular pathways, and performance was better than third party paging systems using Internet connections previously investigated using the same criteria. However, since our study was a best-case assessment, testing is required at individual sites considering use of this technology for critical messaging. Furthermore, since the APN service may fail due to Internet or service provider disruptions, a backup paging system is recommended if the APN service were to be used for critical messaging.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Redes de Comunicación de Computadores
/
Diseño de Software
/
Trabajo de Parto
/
Sistemas de Información en Hospital
/
Teléfono Celular
/
Computadoras de Mano
/
Envío de Mensajes de Texto
/
Anestesia Obstétrica
Tipo de estudio:
Screening_studies
Límite:
Female
/
Humans
/
Pregnancy
Idioma:
En
Revista:
Anesth Analg
Año:
2013
Tipo del documento:
Article
País de afiliación:
Estados Unidos
Pais de publicación:
Estados Unidos