Your browser doesn't support javascript.
loading
Physiology-based MR imaging assessment of CSF flow at the foramen magnum with a valsalva maneuver.
Bhadelia, R A; Madan, N; Zhao, Y; Wagshul, M E; Heilman, C; Butler, J P; Patz, S.
Afiliación
  • Bhadelia RA; Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
AJNR Am J Neuroradiol ; 34(9): 1857-62, 2013 Sep.
Article en En | MEDLINE | ID: mdl-23620074
BACKGROUND AND PURPOSE: MR imaging is currently not used to evaluate CSF flow changes due to short-lasting physiological maneuvers. The purpose of this study was to evaluate the ability of MR imaging to assess the CSF flow response to a Valsalva maneuver in healthy participants. MATERIALS AND METHODS: A cardiac-gated fast cine-PC sequence with ≤15-second acquisition time was used to assess CSF flow in 8 healthy participants at the foramen magnum at rest, during, and immediately after a controlled Valsalva maneuver. CSF mean displacement volume VCSF during the cardiac cycle and CSF flow waveform App were determined. A work-in-progress real-time pencil-beam imaging method with temporal resolution ≤56 ms was used to scan 2 participants for 90 seconds during which resting, Valsalva, and post-Valsalva CSF flow, respiration, and HR were continuously recorded. Results were qualitatively compared with invasive craniospinal differential pressure measurements from the literature. RESULTS: Both methods showed 1) a decrease from baseline in VCSF and App during Valsalva and 2) an increase in VCSF and App immediately after Valsalva compared with values measured both at rest and during Valsalva. Whereas fast cine-PC produced a single CSF flow waveform that is an average over many cardiac cycles, pencil-beam imaging depicted waveforms for each heartbeat and was able to capture many dynamic features of CSF flow, including transients synchronized with the Valsalva maneuver. CONCLUSIONS: Both fast cine-PC and pencil-beam imaging demonstrated expected changes in CSF flow with Valsalva maneuver in healthy participants. The real-time capability of pencil-beam imaging may be necessary to detect Valsalva-related transient CSF flow obstruction in patients with pathologic conditions such as Chiari I malformation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Líquido Cefalorraquídeo / Maniobra de Valsalva / Imagen por Resonancia Cinemagnética / Foramen Magno Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: AJNR Am J Neuroradiol Año: 2013 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Líquido Cefalorraquídeo / Maniobra de Valsalva / Imagen por Resonancia Cinemagnética / Foramen Magno Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: AJNR Am J Neuroradiol Año: 2013 Tipo del documento: Article Pais de publicación: Estados Unidos