Gastric emptying measurement of liquid nutrients using the (13)C-octanoate breath test in critically ill patients: a comparison with scintigraphy.
Nguyen, Nam Q; Bryant, Laura K; Burgstad, Carly M; Chapman, Marianne; Deane, Adam; Bellon, Max; Lange, Kylie; Bartholomeuz, Dylan; Horowitz, Michael; Holloway, Richard H; Fraser, Robert J.
Afiliación
  • Nguyen NQ; Department of Gastroenterology and Hepatology, Royal Adelaide Hospital, North Terrace, Adelaide, South Australia 5000, Australia. quoc.nguyen@health.sa.gov.au
Intensive Care Med ; 39(7): 1238-46, 2013 Jul.
Article en En | MEDLINE | ID: mdl-23471513
PURPOSE: Scintigraphy is considered the most accurate technique for the measurement of gastric emptying (GE) but, for patients in the intensive care unit, it is technically demanding, involves radiation and can interfere with care. The (13)C-octanoate breath test ((13)C-OBT) is a simple, non-invasive technique that does not involve radiation exposure. AIM: To evaluate the performance of the (13)C-OBT in the assessment of GE in critically ill patients. METHODS: The GE was assessed in 33 mechanically ventilated patients (23 M; 54.3 ± 3.0 yrs; APACHE II: 22.0 ± 1.1). Following test meal administration (100 ml Ensure(®)), concurrent scintigraphic measurement and breath samples ((13)C-OBT) were collected over 4 h. Scintigraphic meal retention was determined and the gastric emptying coefficient (GEC) and half emptying time [t50(BT)] were calculated for the (13)C-OBT. Delayed GE was defined as meal retention >13 % at 180 min. RESULTS: Delayed GE was identified in 27/33 patients. Meal retention correlated modestly with t50(BT) (r = 0.55-0.66; P < 0.001) and well with GEC (r = -0.63 to -0.74; P < 0.0001). The strength of agreement between the two techniques was highest between GEC and retention at 120 min. The best cut-off GEC for defining delayed GE was 3.25 (AUC = 0.75; 95 % CI = 0.52-0.99; P = 0.05), with 89 % sensitivity and 67 % specificity to detect delayed GE. The GE was delayed in all (23/23) patients with feed intolerance (GRV > 250 ml) on scintigraphy and 91 % (21/23) patients on (13)C-OBT. CONCLUSION: In critical illness, there was a correlation between (13)C-OBT and gastric scintigraphy, with GEC performing as a better and more sensitive marker of detecting delayed GE than t50. However the relatively wide 95 % confidence intervals suggest that (13)C-OBT is more suitable as a technique to assess GE in a group setting for research studies rather than for individual patients in clinical practice.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pruebas Respiratorias / Enfermedad Crítica / Gastroparesia / Vaciamiento Gástrico Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Intensive Care Med Año: 2013 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pruebas Respiratorias / Enfermedad Crítica / Gastroparesia / Vaciamiento Gástrico Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Intensive Care Med Año: 2013 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Estados Unidos