Fluorescein angiographic findings in eyes of patients with a subretinal electronic implant.
Stingl, Katarina; Gekeler, Florian; Bartz-Schmidt, Karl Ulrich; Kögel, Andreas; Zrenner, Eberhart; Gelisken, Faik.
Afiliación
  • Stingl K; Centre for Ophthalmology, University of Tübingen, Tübingen, Germany. katarina.stingl@med.uni-tuebingen.de
Curr Eye Res ; 38(5): 588-96, 2013 May.
Article en En | MEDLINE | ID: mdl-23410193
PURPOSE: One approach for restoring vision in end-stage hereditary retinal diseases is implantation of a subretinal microphotodiode array. We analyzed retinal fluorescein angiography findings of the implant area. METHODS: In this pilot study, patients (n = 11; 10 men, one woman; ages 45.2 ± 8.7 years), with visual acuity of light perception or worse resulting from a hereditary retinal degenerative disease, received active electronic subretinal visual implants. Implants were removed after 4 weeks (n = 7 subjects) or 4 months (n = 4 subjects). Following implantation, regular fluorescein angiography was performed. Regions of retinal capillary loss, microaneurysms, capillary alterations, neovascularization and leakage over the implant were scored at time points T1 (days 1-14), T2 (days 15-28) and T3 (months 3-4). Occurrence and changes of fluorescein angiographic phenomena are reported. RESULTS: In terms of the number of patients in whom retinal alterations were observed (compared to available images) the occurences of the angiographic phenomena (for time points T1, T2 and T3, respectively) were as follows: regions of capillary loss (five of seven, 10 of 11 and five of five patients), microaneurysms (0 of seven, two of 11 and three of five patients), calibre alterations of the capillaries (three of seven, eight of 11 and five of five patients), retinal neovascularization (one of seven, one of 11 and 0 of five) and leakage (three of seven, seven of 11 and four of five). The Friedman test revealed no significant changes in capillary loss, calibre alteration of the capillaries, neovascularization or leakage. Microaneurysms increased significantly (p = 0.037). CONCLUSIONS: Subretinal visual implants lead to increased capillary microaneurysms, a possible compensatory mechanism following recovery of inner retinal activity. There were no significant changes in capillary loss, calibre alteration of the capillaries, retinal neovascularization and leakage at 4 months. Further study will determine whether and to what degree long-term vascular changes are affected by the surgical procedure, the implant itself and/or recovery of retinal neuronal activity.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vasos Retinianos / Capilares / Angiografía con Fluoresceína / Ceguera / Prótesis Neurales / Aneurisma Tipo de estudio: Diagnostic_studies / Etiology_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Curr Eye Res Año: 2013 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vasos Retinianos / Capilares / Angiografía con Fluoresceína / Ceguera / Prótesis Neurales / Aneurisma Tipo de estudio: Diagnostic_studies / Etiology_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Curr Eye Res Año: 2013 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Reino Unido