Complications of distal radius locking plates.
Injury
; 44(3): 336-9, 2013 Mar.
Article
en En
| MEDLINE
| ID: mdl-23337701
Fixation of distal radius fractures via locking plates is an increasingly popular method. However, these plates include variety of complications, such as flexor and extensor tenosynovitis, tendon injury and intra articular screw or peg penetration. Although they offer superior stability and early mobility, if used improperly; they may cause serious complications related to the implant. Proper use of the implant with strict adherence to the fixation principles and close follow up of patients are very important in order to decrease the rate and severity of complications.