Your browser doesn't support javascript.
loading
Variations in the RBE for cell killing along the depth-dose profile of a modulated proton therapy beam.
Britten, Richard A; Nazaryan, Vahagn; Davis, Leslie K; Klein, Susan B; Nichiporov, Dmitri; Mendonca, Marc S; Wolanski, Mark; Nie, Xiliang; George, Jerry; Keppel, Cynthia.
Afiliación
  • Britten RA; Department of Radiation Oncology, Eastern Virginia Medical School, Norfolk, Virginia 23507, USA. brittera@evms.edu
Radiat Res ; 179(1): 21-8, 2013 Jan.
Article en En | MEDLINE | ID: mdl-23148508
Considerable evidence now exists to show that that the relative biological effectiveness (RBE) changes considerably along the proton depth-dose distribution, with progressively higher RBE values at the distal part of the modulated, or spread out Bragg peak (SOBP) and in the distal dose fall-off (DDF). However, the highly variable nature of the existing studies (with regards to cell lines, and to the physical properties and dosimetry of the various proton beams) precludes any consensus regarding the RBE weighting factor at any position in the depth-dose profile. We have thus conducted a systematic study on the variation in RBE for cell killing for two clinical modulated proton beams at Indiana University and have determined the relationship between the RBE and the dose-averaged linear energy transfer (LETd) of the protons at various positions along the depth-dose profiles. Clonogenic assays were performed on human Hep2 laryngeal cancer cells and V79 cells at various positions along the SOBPs of beams with incident energies of 87 and 200 MeV. There was a marked variation in the radiosensitivity of both cell lines along the SOBP depth-dose profile of the 87 MeV proton beam. Using Hep2 cells, the D(0.1) isoeffect dose RBE values (normalized against (60)Co) were 1.46 at the middle of SOBP, 2.1 at the distal end of the SOBP and 2.3 in the DDF. For V79 cells, the D(0.1) isoeffect RBE for the 87 MEV beam were 1.23 for the proximal end of the SOBP: 1.46 for the distal SOBP and 1.78 for the DDF. Similar D(0.1) isoeffect RBE values were found for Hep2 cells irradiated at various positions along the depth-dose profile of the 200 MeV beam. Our experimentally derived RBE values were significantly correlated (P = 0.001) with the mean LETd of the protons at the various depths, which confirmed that proton RBE is highly dependent on LETd. These in vitro data suggest that the RBE of the proton beam at certain depths is greater than 1.1, a value currently used in most treatment planning algorithms. Thus, the potential for increased cell killing and normal tissue damage in the distal regions of the proton SOBP may be greater than originally thought.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Terapia de Protones Límite: Animals / Humans Idioma: En Revista: Radiat Res Año: 2013 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Terapia de Protones Límite: Animals / Humans Idioma: En Revista: Radiat Res Año: 2013 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos