Your browser doesn't support javascript.
loading
Influence of ridge filter material on the beam efficiency and secondary neutron production in a proton therapy system.
Riazi, Zafar; Afarideh, Hossein; Sadighi-Bonabi, Rasoul.
Afiliación
  • Riazi Z; Department of Nuclear Engineering & Physics, Amirkabir University of Technology, P. O. Box 4155-4494, Tehran, Iran.
Z Med Phys ; 22(3): 231-40, 2012 Sep.
Article en En | MEDLINE | ID: mdl-22739322
In this work, the 3D proton dose profile is calculated in a homogenous water phantom using a Monte Carlo application developed with the Geant4 toolkit. The effect of the ridge filter material (for SOBP widths of 6, 9 and 12cm) on the homogeneity of the dose distribution, secondary neutron production and beam efficiency are investigated in a single ring wobbling irradiation system. The energy spectrum of secondary neutrons per primary proton at various locations around the phantom surface is calculated. The simulation revealed that most of the produced neutrons are released at slight angles which enable them to reach the patient and consequently to be hazardous. Also, the homogeneity of the dose distribution at the proximal edge of spread out Bragg peak (SOBP) field is deteriorated due to the scattering of protons in the ridge filter. It is found that for reducing the above mentioned destructive effects, usage of a PMMA ridge filter is better than Al one. For a similar value of 9cm water equivalent thickness, beam widening radius of Al at isocenter is twice of PMMA. Furthermore, for uniform irradiation of the target, the beam efficiency of the system for Al is less than of PMMA and also regarding to the secondary neutron production PMMA is a better choice.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radioterapia Conformacional / Terapia de Protones / Filtración / Modelos Teóricos / Neutrones Idioma: En Revista: Z Med Phys Asunto de la revista: RADIOTERAPIA Año: 2012 Tipo del documento: Article País de afiliación: Irán Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radioterapia Conformacional / Terapia de Protones / Filtración / Modelos Teóricos / Neutrones Idioma: En Revista: Z Med Phys Asunto de la revista: RADIOTERAPIA Año: 2012 Tipo del documento: Article País de afiliación: Irán Pais de publicación: Alemania