Your browser doesn't support javascript.
loading
Identification of the oxidation products of cysteamine and cystamine by CE-MS interfaced by a noncommercial electrospray ionization source.
Carvalho, Alexandre Zatkovskis; El-Attug, Mohamed Nouri; da Silva, José Alberto Fracassi; Wolfs, Kris; D'Autry, Ward; Hoogmartens, Jos; Adams, Erwin; Van Schepdael, Ann.
Afiliación
  • Carvalho AZ; Faculteit Farmaceutische Wetenschappen, KU Leuven, Belgium. azcarvalho@iqm.unicamp.br
J Sep Sci ; 35(10-11): 1336-43, 2012 Jun.
Article en En | MEDLINE | ID: mdl-22733514
Sodium cysteamine phosphate is a prodrug derivative of cysteamine that can be used in cystinosis treatment. Although titrimetric assays are very well established and precise, iodimetric determination of sodium cysteamine phosphate requires considerably more carefulness and time from the analyst than usual. The possibility to assess sodium cysteamine phosphate by CE was evaluated by means of the quantification of its oxidation product, cystamine, which is a more suitable substance to be used as primary standard than sodium cysteamine phosphate. Apparently, this approach should be straightforward, but systematic differences between the results obtained with CE and titrimetric assays were noticed. MS and CE-MS were employed to aid in the investigation of the possible causes of imprecision of the sodium cysteamine phosphate titration and CE determination. For this purpose, a simple and inexpensive ESI source was constructed. It was observed that cystamine is not the final product of the cysteamine and/or sodium cysteamine phosphate iodine-oxidation and other species besides cystamine may be formed depending on the reaction conditions, which explains the difficulties observed in the sodium cysteamine phosphate quantification.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masa por Ionización de Electrospray / Cistamina / Cisteamina Tipo de estudio: Diagnostic_studies / Evaluation_studies Idioma: En Revista: J Sep Sci Año: 2012 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masa por Ionización de Electrospray / Cistamina / Cisteamina Tipo de estudio: Diagnostic_studies / Evaluation_studies Idioma: En Revista: J Sep Sci Año: 2012 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Alemania