Your browser doesn't support javascript.
loading
[Measurement of the infrapubic angle using 3D perineal ultrasound and its relationship to obstetrical parameters]. / Die Messung des infrapubischen Winkels in der 3-D-Perineal-Sonografie und seine Beziehung zu geburtshilflichen Parametern.
Albrich, S; Laterza, R M; Merinsky, A; Skala, C; Koelbl, H; Naumann, G.
Afiliación
  • Albrich S; Klinik und Poliklinik für Geburtshilfe und Frauenkrankheiten, Universitätsmedizin Mainz, Johannes-Gutenberg-Universität.
  • Laterza RM; OB/GYN, University Mainz.
  • Merinsky A; OB/GYN, University Mainz.
  • Skala C; OB/GYN, University Mainz.
  • Koelbl H; OB/GYN, University Mainz.
  • Naumann G; OB/GYN, University Mainz.
Ultraschall Med ; 33(7): E95-E100, 2012 Dec.
Article en De | MEDLINE | ID: mdl-22723036
PURPOSE: Ultrasound has achieved an indispensable role in urogynecology. The introduction of 3 D technology has enabled sonographers to visualize structures in the axial plane. The angle of the infrapubic arc may enable us to presume the shape of the pelvis. Our aim was to describe a method for measuring the infrapubic angle and the interpubic space with 3 D perineal ultrasound through 3 D rotation, correlating them with the length of the 2nd stage of labor and the rate of levator defects. MATERIALS AND METHODS: Women after vaginal delivery were recruited and underwent a 3 D perineal ultrasound on 2nd - 3 rd day postpartum. Volume datasets were analyzed to measure the infrapubic angle and the interpubic space independently by 2 urogynecologists. The interobserver reliability and the correlation between infrapubic arc angle and the length of the 2nd stage of labor and the occurrence of levator defects were calculated. RESULTS: 110 women were enrolled. With a correlation coefficient of 0.76, the relationship between the infrapubic angle measurements of the two observers was very good. A moderate to good correlation was found for the assessment of the interpubic gap, with r = 0.69. Between the infrapubic angle and length of the 2nd stage of labor, no statistical correlation for both observer measurements (p = 0.31; p = 0.78, respectively) was found. Also the correlation between the infrapubic arc angle and the occurrence of levator avulsions was not significant (p = 0.59; p = 0.39, respectively). CONCLUSION: 3 D ultrasound technology enables us to identify and evaluate the interpubic gap and the infrapubic arc with a high inter-observer reproducibility. However, from our data, the infrapubic angle does not seem to influence the length of the 2nd stage of labor and the occurrence of levator defects.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pelvis / Perineo / Segundo Periodo del Trabajo de Parto / Interpretación de Imagen Asistida por Computador / Ultrasonografía Prenatal / Imagenología Tridimensional Tipo de estudio: Diagnostic_studies Límite: Female / Humans / Pregnancy Idioma: De Revista: Ultraschall Med Año: 2012 Tipo del documento: Article Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pelvis / Perineo / Segundo Periodo del Trabajo de Parto / Interpretación de Imagen Asistida por Computador / Ultrasonografía Prenatal / Imagenología Tridimensional Tipo de estudio: Diagnostic_studies Límite: Female / Humans / Pregnancy Idioma: De Revista: Ultraschall Med Año: 2012 Tipo del documento: Article Pais de publicación: Alemania