Congenital heart disease: cardiovascular MR imaging by using an intravascular blood pool contrast agent.
Radiology
; 260(3): 680-8, 2011 Sep.
Article
en En
| MEDLINE
| ID: mdl-21613441
PURPOSE: To compare the image quality and diagnostic performance of a contrast agent-specific inversion-recovery (IR) steady-state free precession (SSFP) magnetic resonance (MR) imaging sequence performed by using an intravascular contrast agent (gadofosveset trisodium) with those of a commonly used T2-prepared SSFP sequence performed by using an extravascular (gadopentetate dimeglumine) and an intravascular (gadofosveset trisodium) contrast agent in patients with congenital heart disease (CHD). MATERIALS AND METHODS: The local ethics committee and the United Kingdom Medicines and Healthcare products Regulatory Agency approved this study. Patient informed consent was obtained. Twenty-three patients with CHD were examined by using a 1.5-T MR imaging unit and a 32-channel coil. Gadopentetate dimeglumine and gadofosveset trisodium were used in the same patient on consecutive days. Vessel wall sharpness, contrast-to-noise ratios (CNRs), image quality, and diagnostic performance achieved by using the IR SSFP sequence with gadofosveset trisodium were compared with those achieved by using the T2-prepared SSFP sequence with gadopentetate dimeglumine and gadofosveset trisodium and with those achieved at respective contrast material-enhanced MR angiographic examinations. The Wilcoxon rank sum test was used to compare categoric variables; t tests were used to compare continuous variables. RESULTS: Use of the IR SSFP sequence with gadofosveset trisodium significantly improved vessel wall sharpness, CNRs, and image quality (P < .05 for all) for all investigated intra- and extracardiac structures compared with the T2-prepared SSFP sequence with gadopentetate dimeglumine and gadofosveset trisodium and the respective contrast-enhanced MR angiographic examinations. With use of the IR SSFP sequence with gadofosveset trisodium, new, unsuspected diseases (five [22%] of 23) were diagnosed, while other diseases could be excluded (15 [65%] of 23). Information available from echocardiography (n = 23), conventional angiography (n = 4), and/or surgery (n = 1) confirmed all diagnoses. CONCLUSION: IR SSFP with gadofosveset trisodium improved image quality and diagnostic performance, allowing a more accurate and complete assessment of cardiovascular anatomy in patients with CHD compared with T2-prepared SSFP with gadopentetate dimeglumine and gadofosveset trisodium and respective contrast-enhanced MR angiographic examinations.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Compuestos Organometálicos
/
Imagen por Resonancia Magnética
/
Aumento de la Imagen
/
Gadolinio
/
Cardiopatías Congénitas
Tipo de estudio:
Diagnostic_studies
Aspecto:
Ethics
Límite:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Radiology
Año:
2011
Tipo del documento:
Article
País de afiliación:
Reino Unido
Pais de publicación:
Estados Unidos