Your browser doesn't support javascript.
loading
Prevention of intraprocedural puncture site bleeding during arterial port implantation by use of a suture-mediated arterial closure system: a prospective randomized trial.
Dudeck, Oliver; Wilhelmsen, Skadi; Stübs, Patrick; Kuhn, Roger; Liehr, Bernd-Uwe; Bischoff, Joachim; Bonnekoh, Bernd; Ricke, Jens; Pech, Maciej.
Afiliación
  • Dudeck O; Department of Radiology and Nuclear Medicine, University of Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany. oliver.dudeck@med.ovgu.de
J Vasc Interv Radiol ; 22(10): 1409-13, 2011 Oct.
Article en En | MEDLINE | ID: mdl-21514842
PURPOSE: To investigate a modified technique for arterial port placement that uses a suture-mediated closure system with the aim to reduce delays caused by intraprocedural oozing around the catheter. MATERIALS AND METHODS: Forty consecutive patients (age, 63.9 y ± 11.8) stratified for regional arterial infusion chemotherapy were prospectively randomized to undergo conventional or modified port implantation. Time for device placement, total procedure time, number of catheters, size of largest and final catheters placed, duration of bleeding from puncture site, procedural delays, and time until hemostasis was achieved were recorded. RESULTS: Time for device placement was 3.7 minutes ± 1.1, with no complications encountered. Total procedure times were 133.0 minutes ± 62.8 for conventional port implantation and 100.0 minutes ± 49.5 for modified implantation (P = .13). No differences were found in the number of catheters or size of largest or final catheter used. Duration of groin bleeding necessitating manual compression was 21.8 minutes ± 24.4 for conventional port implantation, resulting in a mean procedural delay of 6.2 minutes ± 7.0. Hemostasis was achieved after a mean of 17.1 minutes ± 20.9. Groin hematoma was observed in three patients. In contrast, with the modified technique, mean duration of oozing and intraprocedural delays were only 0.2 minutes ± 0.6 and 0.1 minutes ± 0.5, respectively (both P < .0001 vs conventional technique). Hemostasis was achieved within 3.2 minutes ± 4.1 (P < .0001), with no cases of hematoma found. CONCLUSIONS: Use of a suture-mediated closure system facilitated arterial port implantation by effective prevention of groin bleeding while allowing the use of a sheath.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Quimioterapia del Cáncer por Perfusión Regional / Técnicas Hemostáticas / Técnicas de Sutura / Ingle / Hemorragia Tipo de estudio: Clinical_trials / Etiology_studies / Observational_studies Límite: Aged / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: J Vasc Interv Radiol Asunto de la revista: ANGIOLOGIA / RADIOLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Quimioterapia del Cáncer por Perfusión Regional / Técnicas Hemostáticas / Técnicas de Sutura / Ingle / Hemorragia Tipo de estudio: Clinical_trials / Etiology_studies / Observational_studies Límite: Aged / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: J Vasc Interv Radiol Asunto de la revista: ANGIOLOGIA / RADIOLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos