Your browser doesn't support javascript.
loading
SNR dependence of optimal parameters for apparent diffusion coefficient measurements.
Saritas, Emine U; Lee, Jin H; Nishimura, Dwight G.
Afiliación
  • Saritas EU; Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA. saritas@berkeley.edu
IEEE Trans Med Imaging ; 30(2): 424-37, 2011 Feb.
Article en En | MEDLINE | ID: mdl-20934948
Optimizing the diffusion-weighted imaging (DWI) parameters (i.e., the b-value and the number of image averages) to the tissue of interest is essential for producing high-quality apparent diffusion coefficient (ADC) maps. Previous investigation of this optimization was performed assuming Gaussian noise statistics for the ADC map, which is only valid for high signal-to-noise ratio (SNR) imaging. In this work, the true statistics of the noise in ADC maps are derived, followed by an optimization of the DWI parameters as a function of the imaging SNR. Specifically, it is demonstrated that the optimum b-value is a monotonically increasing function of the imaging SNR, which converges to the optimum b-value from previously proposed approaches for high-SNR cases, while exhibiting a significant deviation from this asymptote for low-SNR situations. Incorporating the effects of T(2) weighting further increases the SNR dependence of the optimal parameters. The proposed optimization scheme is particularly important for high-resolution DWI, which intrinsically suffers from low SNR and therefore cannot afford the use of the conventional high b-values. Comparison scans were performed for high-resolution DWI of the spinal cord, demonstrating the improvements in the resulting images and the ADC maps achieved by this method.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Procesamiento de Señales Asistido por Computador / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: IEEE Trans Med Imaging Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Procesamiento de Señales Asistido por Computador / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: IEEE Trans Med Imaging Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos