Your browser doesn't support javascript.
loading
Fiber-optic particle plasmon resonance sensor for detection of interleukin-1ß in synovial fluids.
Chiang, Chang-Yue; Hsieh, Ming-Lung; Huang, Kuo-Wei; Chau, Lai-Kwan; Chang, Chia-Ming; Lyu, Shaw-Ruey.
Afiliación
  • Chiang CY; Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi 62102, Taiwan.
Biosens Bioelectron ; 26(3): 1036-42, 2010 Nov 15.
Article en En | MEDLINE | ID: mdl-20833017
A facile and label-free biosensing method has been developed for determining an osteoarthritis concerned cytokine, interleukin-1ß (IL-1ß), in synovial fluids. The biosensing technique, fiber-optic particle plasmon resonance (FOPPR), is based on gold nanoparticles-modified optical fiber where the gold nanoparticle surface has been modified by a mixed self-assembled monolayer for further conjugation of anti-IL-1ß antibody and minimization of nonspecific adsorption. Upon binding of IL-1ß to anti-IL-1ß on the gold nanoparticle surface, the absorbance of the gold nanoparticle layer on the optical fiber changes and the signal change is enhanced through multiple total internal reflections along the optical fiber. Results show that the detection of IL-1ß in synovial fluid by this sensor agrees quantitatively with the clinically accepted enzyme-linked immunosorbent assay (ELISA) method but a much shorter analysis time is required (<10 min). The sensor response versus log concentration of IL-1ß was linear (r=0.9947) over the concentration range of 0.050-10 ng/mL and a limit of detection (LOD) of 21 pg/mL (1.2 pM) was achieved. Such a LOD for IL-1ß (17 kDa) represents a major advancement in the field of real-time monitoring of low molecular weight proteins in complex biological fluids.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Líquido Sinovial / Resonancia por Plasmón de Superficie / Interleucina-1beta / Fibras Ópticas Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Taiwán Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Líquido Sinovial / Resonancia por Plasmón de Superficie / Interleucina-1beta / Fibras Ópticas Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Taiwán Pais de publicación: Reino Unido