Your browser doesn't support javascript.
loading
Effect of right ventricular dysfunction on dynamic preload indices to predict a decrease in cardiac output after inferior vena cava clamping during liver transplantation.
Kim, Y K; Shin, W J; Song, J G; Jun, I G; Kim, H Y; Seong, S H; Huh, I Y; Hwang, G S.
Afiliación
  • Kim YK; Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Transplant Proc ; 42(7): 2585-9, 2010 Sep.
Article en En | MEDLINE | ID: mdl-20832549
BACKGROUND: Dynamic preload indices such as stroke volume variation (SVV) and pulse pressure variation (PPV) have yielded false-positive results in patients with right ventricular (RV) dysfunction. We therefore assessed the effect of RV dysfunction on dynamic indices to predict the decrease in cardiac output (CO) during liver transplantation. METHODS: Hemodynamic parameters were measured before and after inferior vena cava (IVC) clamping in 52 recipients. The RV dysfunction was defined as an RV ejection fraction (RVEF) ≤ 30%. The area under the receiver operating characteristic curve (AUC) sufficient to detect changes in CO (ΔCO) ≥ 20% after IVC clamping in recipients was calculated. RESULTS: Recipients with RVEF ≤ 30% did not show significant increases in SVV or PPV despite having ΔCO ≥ 20%. In recipients with RVEF > 30%, the threshold value and AUC of SVV predicting a decrease in CO were 10% and 0.755 (compared with an AUC of 0.5, P = .011), respectively, whereas those for PPV were 10% and 0.767 (P = .007), respectively. However, in recipients with RVEF ≤ 30%, the threshold value and AUC of SVV were 10% and 0.638 (P = .305), respectively, whereas those for PPV were 12% and 0.684 (P = .159), respectively. CONCLUSIONS: These results suggest that dynamic preload indices may not be sufficiently sensitive to detect a CO decrease in liver transplant recipients with RV dysfunction, emphasizing the importance of evaluating RV function when determining the predictability of dynamic indices.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Volumen Sistólico / Gasto Cardíaco / Trasplante de Hígado / Disfunción Ventricular Derecha Tipo de estudio: Etiology_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Transplant Proc Año: 2010 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Volumen Sistólico / Gasto Cardíaco / Trasplante de Hígado / Disfunción Ventricular Derecha Tipo de estudio: Etiology_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Transplant Proc Año: 2010 Tipo del documento: Article Pais de publicación: Estados Unidos