Unstable resonator alignment study using off-axis injection.
Appl Opt ; 30(30): 4302-9, 1991 Oct 20.
Article en En | MEDLINE | ID: mdl-20717200
A brief qualitative experiment and subsequent theoretical study provide new insight concerning off-axis injection of unstable resonators. Theoretical results for aligned resonators show that the regurgitated beam intensity distribution and direction of travel are sensitive to the size, tilt, and other parameters of the injected beam, to the coherence length and number of longitudinal modes of the injecting laser, to clipping and diffraction from apertures, and to resonator length tuning. It is concluded that visual observations of output asymmetries can be used to align the resonator to some degree, but precise alignment using measurement of output asymmetries by a detector array is questionable.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Qualitative_research Idioma: En Revista: Appl Opt Año: 1991 Tipo del documento: Article Pais de publicación: Estados Unidos