Effect of variation in argon content of calibration gases on determination of atmospheric carbon dioxide.
Min, Deullae; Kang, Namgoo; Moon, Dong Min; Lee, Jin Bok; Lee, Dong Soo; Kim, Jin Seog.
Afiliación
  • Min D; Center for Gas Analysis, Division of Metrology for Quality of Life, Korea Research Institute of Standards and Science, Yuseong-Gu, Daejeon, Republic of Korea.
Talanta ; 80(2): 422-7, 2009 Dec 15.
Article en En | MEDLINE | ID: mdl-19836498
Carbon dioxide (CO(2)) is a greenhouse gas that makes by far the largest contribution to the global warming of the Earth's atmosphere. For the measurements of atmospheric CO(2) a non-dispersive infrared analyzer (NDIR) and gas chromatography are conventionally being used. We explored whether and to what degree argon content can influence the determination of atmospheric CO(2) using the comparison of CO(2) concentrations between the sample gas mixtures with varying Ar amounts at 0 and 18.6 mmol mol(-1) and the calibration gas mixtures with Ar at 8.4, 9.1, and 9.3 mmol mol(-1). We newly discovered that variation of Ar content in calibration gas mixtures could undermine accuracy for precise and accurate determination of atmospheric CO(2) in background air. The differences in CO(2) concentration due to the variation of Ar content in the calibration gas mixtures were negligible (<+/-0.03 micromol mol(-1)) for NDIR systems whereas they noticeably increased (<+/-1.09 micromol mol(-1)) especially for the modified GC systems to enhance instrumental sensitivity. We found that the thermal mass flow controller is the main source of the differences although such differences appeared only in the presence of a flow restrictor in GC systems. For reliable monitoring of real atmospheric CO(2) samples, one should use calibration gas mixtures that contain Ar content close to the level (9.332 mmol mol(-1)) in the ambient air as possible. Practical guidelines were highlighted relating to selection of appropriate analytical approaches for the accurate and precise measurements of atmospheric CO(2). In addition, theoretical implications from the findings were addressed.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Argón / Dióxido de Carbono / Gases Tipo de estudio: Guideline / Prognostic_studies Idioma: En Revista: Talanta Año: 2009 Tipo del documento: Article Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Argón / Dióxido de Carbono / Gases Tipo de estudio: Guideline / Prognostic_studies Idioma: En Revista: Talanta Año: 2009 Tipo del documento: Article Pais de publicación: Países Bajos