[The use of uncemented extensively porous-coated femoral components in the management of Vancouver type B2 periprosthetic femoral fractures].
Zhonghua Wai Ke Za Zhi
; 47(3): 181-4, 2009 Feb 01.
Article
en Zh
| MEDLINE
| ID: mdl-19563070
OBJECTIVE: To assess the outcome of patients with Vancouver type B2 periprosthetic fractures treated with femoral revision using an uncemented extensively porous-coated implant. METHODS: From October 2002 to May 2007, a retrospective clinical and radiographic assessment of 10 patients with Vancouver type B2 periprosthetic fractures treated with femoral revision was evaluated, among which 4 was cement fixation, 6 was non-cement fixation in the index procedure. RESULTS: The mean follow-up for these patients was 44 months (range, 12 to 67 months). The mean Harris hip score was 87.6 points. All 10 reconstructions showed solid fracture union and a stable prosthesis, 8 was bone ingrowth, 2 was fibrous ingrowth. Complications in 4 patients included thigh pain in 1, stress shield in 3. CONCLUSIONS: Vancouver type B2 periprosthetic fractures treated with uncemented extensively porous-coated femoral stems incorporate distally allowing stable fixation.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Fracturas Periprotésicas
/
Fracturas del Fémur
/
Prótesis de Cadera
Tipo de estudio:
Observational_studies
/
Prognostic_studies
Límite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
Zh
Revista:
Zhonghua Wai Ke Za Zhi
Año:
2009
Tipo del documento:
Article
País de afiliación:
China
Pais de publicación:
China