Your browser doesn't support javascript.
loading
A non-invasive device to objectively measure tibial rotation: verification of the device.
Lorbach, Olaf; Wilmes, P; Maas, S; Zerbe, T; Busch, L; Kohn, D; Seil, R.
Afiliación
  • Lorbach O; Department of Orthopedic Surgery, Saarland University, Homburg/Saar, Germany. olaf.lorbach@gmx.de
Knee Surg Sports Traumatol Arthrosc ; 17(7): 756-62, 2009 Jul.
Article en En | MEDLINE | ID: mdl-19266183
The purpose of this study was the correlation of the results of a new measurement device for tibial rotation (Rotameter) in comparison with the measurements of a knee navigation system as standard method. In a biomechanical laboratory study, all soft tissues were removed from 20 human cadaveric knees leaving only the intact capsule and the bone. Specific tracers were bicortically fixed in the bone in order to measure tibial rotation using a knee navigation system. The knees were fixed to a custom-made inside-boot to rule out undesirable rotation of the reconstruction inside the Rotameter measurement device. Internal and external rotation values were measured at an applied torque of 5, 10 and 15 Nm. The different methods to evaluate tibial rotation were compared using the Pearson correlation coefficient. The correlations were deemed to be reliable if a value of >or=0.80 was achieved. At 5 Nm of applied torque, high correlations for the internal rotation, external rotation and the entire rotational range were found in the Pearson correlation coefficient between the Rotameter testing device in comparison with the knee navigation system as invasive reference method. These results were also confirmed at an applied torque of 10 and 15 Nm. In conclusion, the Rotameter testing device showed high correlations compared with the knee navigation system as an invasive standard method. It might be used as a non-invasive and easy alternative to investigate tibial rotation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tibia / Artrometría Articular / Articulación de la Rodilla Tipo de estudio: Evaluation_studies Límite: Humans Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Asunto de la revista: MEDICINA ESPORTIVA / TRAUMATOLOGIA Año: 2009 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tibia / Artrometría Articular / Articulación de la Rodilla Tipo de estudio: Evaluation_studies Límite: Humans Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Asunto de la revista: MEDICINA ESPORTIVA / TRAUMATOLOGIA Año: 2009 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania