The safety and efficacy of an extravascular, water-soluble sealant for vascular closure: initial clinical results for Mynx.
Scheinert, D; Sievert, H; Turco, M A; Schmidt, A; Hauptmann, K E; Mueller, R; Dadourian, D; Krankenberg, H; Grube, E.
Afiliación
  • Scheinert D; Department of Angiology, Heart Center, University of Leipzig, Leipzig, Germany. sched@medizin.uni-leipzig.de
Catheter Cardiovasc Interv ; 70(5): 627-33, 2007 Nov 01.
Article en En | MEDLINE | ID: mdl-17960627
OBJECTIVE: The purpose of this study was to evaluate the hemostatic efficacy and safety of the Mynx extravascular sealant for femoral artery closure. BACKGROUND: The Mynx device is an extra-arterial vascular closure technology utilizing a water-soluble, porous, polyethylene glycol matrix that immediately seals the arteriotomy by rapidly absorbing subcutaneous fluids and expanding in the tissue tract and then, resorbs within 30 days. METHODS: The Mynx study was a prospective, multicenter, single-arm clinical investigation conducted at five European centers. The safety and effectiveness of the Mynx device was evaluated in patients following diagnostic or interventional endovascular procedures performed through 5 Fr, 6 Fr, or 7 Fr introducer sheaths in the common femoral artery. The primary safety endpoint was the combined rate of major complications within 30 days (+/-7 days). The primary efficacy endpoints were time to hemostasis and time to ambulation. RESULTS: Patient enrollment included 190 patients with 50% having undergone diagnostic catheterization and 50% interventional procedures with a mean activated clotting time of 221 sec. One (0.5%) major vascular complication (transfusion) occurred in one patient. No device-precipitated complications associated with serious clinical sequelae were reported. Mean (+/- standard deviation) times to hemostasis and ambulation were 1.3 +/- 2.3 min and 2.6 +/- 2.6 hr, respectively. There was no significant difference in median times to hemostasis between diagnostic and interventional patients (0.5 vs. 0.6 min). CONCLUSIONS: The initial experience with the extra-arterial Mynx closure technology supports hemostatic safety and efficacy in patients undergoing diagnostic and interventional catheterization procedures.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Instrumentos Quirúrgicos / Cateterismo Cardíaco / Técnicas Hemostáticas / Arteria Femoral Tipo de estudio: Clinical_trials / Evaluation_studies / Observational_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2007 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Instrumentos Quirúrgicos / Cateterismo Cardíaco / Técnicas Hemostáticas / Arteria Femoral Tipo de estudio: Clinical_trials / Evaluation_studies / Observational_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2007 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos