[Comparison of the two methods, LASIK and ICL in mild and high hyperopia correction--part one]. / Srovnání metody LASIK a implantace ICL pri korekci strední a vysoké hyperopie. I. cást.
Cesk Slov Oftalmol
; 63(3): 143-53, 2007 May.
Article
en Cs
| MEDLINE
| ID: mdl-17621829
The problems of hyperopia surgical correction are complicated. The most used methods are corneal laser treatments (PRK and LASIK), phakic intraocular lenses or clear lens extraction (CLE). The aim of the study was to evaluate and to compare long-term postoperative results of two types of refractive procedures in mild and high hyperopia correction: LASIK and ICL (phakic intraocular posterior chamber contact lens) implantation. The authors evaluated a group of 37 eyes of 20 patients; the average age was 36.3 years +/- 11.8 (SD) and the follow-up period 28.1 months +/- 10.2 (SD) after LASIK procedure, and group of 21 eyes of 13 patients; the average age was 28.6 years +/- 6.1 (SD) and the follow-up period 30.4 months +/- 20.9 (SD) after the ICL implantation. The final uncorrected (UCVA) and best-corrected visual acuity (BCVA) and postoperative refractive error (for far and near) and their development in time were compared. They found statistically significant improvement of the UCVA postoperatively comparing to the preoperative values in both methods (LASIK and ICL) (p < 0.05). Better UCVA was achieved by means of ICL implantation (p < 0.05). The BCVA improved after the ICL implantation only (p > 0.05). In hyperopic LASIK, the final BCVA worsened comparing to this before treatment (p > 0.05). The BCVA changes were not statistically significant. The authors also proved better final spherical refraction for far (p < 0.05 in the first and second year) and for the near as well (p < 0.05 in the first and second year) in the ICL method comparing to the hyperopic LASIK. The stableness of the postoperative refraction was better after the ICL implantation during the whole follow up period. In the laser treatment, the continuous regression of the postoperative refraction was evident. The final cylindrical refraction value was also lower in the ICL group (p > 0.05). The stableness of the postoperative cylindrical refraction was also higher in the ICL method during the whole follow up period. Comparing the intraocular procedure (ICL) to the laser method (LASIK), the ICL implantation demonstrates better final BCVA and UCVA and the postoperative refraction is more stable.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Implantación de Lentes Intraoculares
/
Queratomileusis por Láser In Situ
/
Hiperopía
Límite:
Adult
/
Humans
Idioma:
Cs
Revista:
Cesk Slov Oftalmol
Asunto de la revista:
OFTALMOLOGIA
Año:
2007
Tipo del documento:
Article
Pais de publicación:
República Checa