Your browser doesn't support javascript.
loading
MRI relaxation fluctuations in acute reperfused hemorrhagic infarction.
Foltz, W D; Yang, Y; Graham, J J; Detsky, J S; Wright, G A; Dick, A J.
Afiliación
  • Foltz WD; Department of Cardiology, St. Michael's Hospital, University of Toronto, Toronto, Canada. warren.foltz@sw.ca
Magn Reson Med ; 56(6): 1311-9, 2006 Dec.
Article en En | MEDLINE | ID: mdl-17089360
MRI evaluations of intramyocardial hemorrhage in acute infarction have relied on T(2) and T(2)(*) shortening only. We propose a more comprehensive evaluation of hemorrhagic infarction based on the concept that fluctuations in T(2) and T(1) relaxation in acute reperfused infarction will reflect transient edema and hemoglobin oxidative denaturation to uncompartmentalized methemoglobin. Anteroapical infarction was created via percutaneous balloon in young swine (22-25 kg, N = 12). T(2), T(1), diastolic wall thickness (DWT), and the Gd-DTPA partition coefficient (lambda) were measured on days 0, 2, and 7. DWT was elevated at 1 hr postreperfusion (128% +/- 53%, P = 0.0001), and alleviated on days 2 and 7 (48% +/- 10%, P = 0.008; 53% +/- 24%, P = 0.003). T(2) and T(1) elevations were coincident with early edema (DeltaT(2) = 55% +/- 24%, P < 0.0001; DeltaT(1) = 27% +/- 18%, P < 0.04). T(2) and T(1) were nearly normal on day 2 (DeltaT(2) = 8% +/- 8%, P = 0.27; DeltaT(1) = 0% +/- 1%, P = 0.65). On day 7, T(2) increased while T(1) decreased (DeltaT(2) = 27% +/- 16%, P = 0.005; DeltaT(1) = -14% +/- 10%, P = 0.02). Lambda was elevated by >150% at all time points (P < or = 0.002). Histology verified hemorrhagic injury. T(1) and T(2) fluctuations are consistent with transient edema, as well as hemoglobin oxidative denaturation to decompartmentalized methemoglobin. This methodological development may broaden our understanding of hemorrhagic microvascular injury and improve its detection in clinical populations.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Daño por Reperfusión Miocárdica / Hemorragia / Infarto del Miocardio Tipo de estudio: Diagnostic_studies / Etiology_studies Límite: Animals Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2006 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Daño por Reperfusión Miocárdica / Hemorragia / Infarto del Miocardio Tipo de estudio: Diagnostic_studies / Etiology_studies Límite: Animals Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2006 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Estados Unidos