Inhomogeneous plastic flow investigated by X-ray absorption microtomography of an aluminium alloy containing marker particles.
Haldrup, K; Nielsen, S F; Beckmann, F; Wert, J A.
Afiliación
  • Haldrup K; Center for Fundamental Research, Risø National Laboratory, 4000 Roskilde, Denmark. kristoffer.haldrup@risoe.dk
J Microsc ; 222(Pt 1): 28-35, 2006 Apr.
Article en En | MEDLINE | ID: mdl-16734711
By combining a synchrotron X-ray source and the microtomography technique, the displacement gradient tensor components can be measured directly throughout the volume of a metal sample containing highly absorbing marker particles to detect material flow. The present article describes application of these techniques to compression of a rectangular Al-W specimen with a central hole. The results show that the externally imposed axial displacement gradient is accommodated mainly in two 45 degrees shear bands passing through the hole. A simple deformation analysis provides insight into shear band formation.
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Microsc Año: 2006 Tipo del documento: Article País de afiliación: Dinamarca Pais de publicación: Reino Unido