Characterization of a 20 kHz sonoreactor. Part I: analysis of mechanical effects by classical and numerical methods.
Sáez, V; Frías-Ferrer, A; Iniesta, J; González-García, J; Aldaz, A; Riera, E.
Afiliación
  • Sáez V; Grupo de Electroquímica Aplicada y Electrocatálisis, Departamento de Química Física, Universidad de Alicante, Ap. Correos 99, 03080 Alicante, Spain.
Ultrason Sonochem ; 12(1-2): 59-65, 2005 Jan.
Article en En | MEDLINE | ID: mdl-15474953
Numerical simulations have been carried out in order to characterize the ultrasonic field propagation and to obtain the spatial distribution of the mechanical effect derived from it. The results have been compared with those obtained with different classical physical methods (calorimetry, aluminium foil erosion, thermal probes) and have given useful information about the influence of the presence of probes and auxiliary tools in the ultrasonic field. All these information have been used for the development of the Part II of this work: analysis of chemical effects, providing an accurate picture of the reaction environment in the sonoreactor used (20 kHz, 100 W supplied by Undatim) for further uses in sonoelectrochemical studies.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sonicación / Ensayo de Materiales / Análisis de Falla de Equipo / Aluminio / Modelos Químicos Tipo de estudio: Evaluation_studies Idioma: En Revista: Ultrason Sonochem Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2005 Tipo del documento: Article País de afiliación: España Pais de publicación: Países Bajos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sonicación / Ensayo de Materiales / Análisis de Falla de Equipo / Aluminio / Modelos Químicos Tipo de estudio: Evaluation_studies Idioma: En Revista: Ultrason Sonochem Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2005 Tipo del documento: Article País de afiliación: España Pais de publicación: Países Bajos