The self-inflating bulb as an esophageal detector device in children weighing more than twenty kilograms: a comparison of two techniques.
Ann Emerg Med
; 41(5): 623-9, 2003 May.
Article
en En
| MEDLINE
| ID: mdl-12712028
STUDY OBJECTIVES: We confirm the ability of the self-inflating bulb to indicate endotracheal tube position in children and determine which method of bulb compression is more accurate. METHODS: This single-blind, prospective, single cohort, repeated measures comparison of the on-deflate and the off-deflate methods of bulb compression was conducted in the operating room of a children's hospital. Seventy-five patients weighing more than 20 kg were enrolled. All patients had an endotracheal tube placed in both the trachea and the esophagus, 5 mL/kg of air was insufflated into the stomach, and 4 measurements were obtained on each patient. The bulb was either applied to the endotracheal tube and then compressed (on-deflate method), or compressed before its attachment to the endotracheal tube (off-deflate method). The order in which the methods were utilized was determined by a computer-generated permuted block randomization scheme. The blinded assessor told the anesthesiologist when to start and stop the clock after each intervention. Five seconds was used as the cut-off time for which the clock was stopped. If the bulb reexpanded within 5 seconds, then the tube was considered to be in the trachea; if it did not reexpand, then this was considered to be an esophageal intubation. RESULTS: The mean patient age was 11 years. The on-deflate method had a sensitivity of 99% and a specificity of 92% for detecting tracheal intubations. The off-deflate method had a sensitivity of 99% and a specificity of 100% (95% confidence interval [CI] for the difference between methods: sensitivity -6 to 6, specificity -14 to 0.4). The inaccuracy rate for the off-deflate method was 1%, whereas the inaccuracy rate for the on-deflate method was 5% (Delta4; 95% CI 0.2 to 9). CONCLUSION: The self-inflating bulb is a reliable method of detecting endotracheal tube position in children. Furthermore, the off-deflate method may be more reliable and accurate than the on-deflate method when used in children weighing more than 20 kg.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Peso Corporal
/
Esófago
/
Intubación Intratraqueal
Tipo de estudio:
Clinical_trials
/
Diagnostic_studies
/
Observational_studies
Límite:
Adolescent
/
Child
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Ann Emerg Med
Año:
2003
Tipo del documento:
Article
País de afiliación:
Estados Unidos
Pais de publicación:
Estados Unidos