Your browser doesn't support javascript.
loading
Multidipole analysis of simulated epileptic spikes with real background activity.
Stephen, J M; Aine, C J; Ranken, D; Hudson, D; Shih, Jerry J.
Afiliación
  • Stephen JM; Department of Radiology, University of New Mexico School of Medicine, New Mexico VA Health Care System, Albuquerque, New Mexico, USA.
J Clin Neurophysiol ; 20(1): 1-16, 2003 Feb.
Article en En | MEDLINE | ID: mdl-12684553
This simulated magnetoencephalographic study was designed to determine the variability in source parameters with real subject background activity when applying multidipole spatial-temporal dipole analyses, for which the correct model was compared with undermodeled and overmodeled cases. The simulated sources were created from patches of the cortical surface of each subject's MRI. One- and two-source frontal lobe spikes were generated in two cortical regions seen commonly in frontal lobe epilepsy patients tested at our site (orbital frontal and premotor cortex). In general, the modeling results were adequate for the correct model order and the correct model order plus one. In addition, if the localization error was less than 10 mm from the simulated source, the peak latency of the spike and orientation were very reliable, but the peak amplitude was not. The additional source in the overmodeled condition, on the other hand, was not localized reliably across the different epochs within subjects. The results suggest that consistency of the spike localization and inconsistency of other sources will allow one to determine reliably the appropriate model order in real data, and therefore determine single and multifocal spike generators.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Simulación por Computador / Mapeo Encefálico / Magnetoencefalografía / Epilepsia del Lóbulo Frontal / Modelos Neurológicos Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Clin Neurophysiol Asunto de la revista: FISIOLOGIA / NEUROLOGIA Año: 2003 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Simulación por Computador / Mapeo Encefálico / Magnetoencefalografía / Epilepsia del Lóbulo Frontal / Modelos Neurológicos Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Clin Neurophysiol Asunto de la revista: FISIOLOGIA / NEUROLOGIA Año: 2003 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos