Your browser doesn't support javascript.
loading
Efficacy of antibiotic-lock technique with teicoplanin in staphylococcus epidermidis catheter-related sepsis during long-term parenteral nutrition.
Guedon, C; Nouvellon, M; Lalaude, O; Lerebours, E.
Afiliación
  • Guedon C; Hépato-Gastroenterology and Nutrition Unit, Hospital Charles Nicolle, Rouen, France. claire.guedon@chu-rouen.fr
JPEN J Parenter Enteral Nutr ; 26(2): 109-13, 2002.
Article en En | MEDLINE | ID: mdl-11871734
BACKGROUND: The antibiotic-lock technique has been suggested to treat catheter-related sepsis in parenteral nutrition and to avoid catheter removal. METHODS: To determine the incidence of catheter-related sepsis, the bacteria involved, and the efficacy of the antibiotic-lock technique with teicoplanin, all patients (n = 263) undergoing parenteral nutrition from January 1997 to December 1999 in one center, with patients at the hospital (n = 209) and at home (54) were retrospectively studied. The antibiotic-lock technique with teicoplanin was systematically used in all suspected infections and maintained in staphylococcus epidermidis (SE) infections. RESULTS: A total of 21 of 263 patients had 34 infections (0.11/patient per year): 12 of 209 hospitalized and 9 of 54 home patients. A total of 10 of 34 infections were due to non-SE, and the catheter was immediately removed. The other 24 of 34 infections were due to SE; in 5 of 24, the catheter was removed after 48 hours of the antibiotic-lock technique because of persistent fever or thrombosis. A total of 5 of 12 patients had 2 or more infections on the same catheter. The antibiotic-lock technique prevented short-term catheter removal in these cases, but a second infection occurred within a median of 50 days. In 4 of 5 cases, a third infection occurred in a mean delay of 90 days so that the catheter was removed. In 3 of 5 patients, bacteria was analyzed with pulsed field gel electrophoresis, which showed that recurrent infections were due to the same strain in all cases. CONCLUSIONS: In this study, the incidence of catheter-related sepsis was low and mostly related to SE. Our results do not support the use of the teicoplanin antibiotic-lock technique in SE infections.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones Estafilocócicas / Cateterismo / Nutrición Parenteral / Teicoplanina / Antibacterianos Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: JPEN J Parenter Enteral Nutr Año: 2002 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones Estafilocócicas / Cateterismo / Nutrición Parenteral / Teicoplanina / Antibacterianos Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: JPEN J Parenter Enteral Nutr Año: 2002 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Estados Unidos