Your browser doesn't support javascript.
loading
Long-term results with the Xenomedica porcine bioprosthesis in the mitral position.
Santini, F; Auriemma, S; Casali, G; Rossi, A; Lusini, M; Mazzucco, A.
Afiliación
  • Santini F; Division of Cardiac Surgery, University of Verona Medical School, Italy.
J Heart Valve Dis ; 10(6): 789-94, 2001 Nov.
Article en En | MEDLINE | ID: mdl-11767188
BACKGROUND AND AIM OF THE STUDY: The study aim was to evaluate our clinical experience with the Xenomedica heart valve prosthesis, a low-pressure glutaraldehyde-preserved porcine aortic valve with low-profile mounting. METHODS: Between January 1983 and July 1990, 242 consecutive patients (75 men, 167 women; mean age 59.8+/-8.0 years; range: 32-77 years) underwent mitral valve replacement with the Xenomedica prosthesis. Preoperatively, patients were in NYHA classes III (66%) and IV (26%); 94 patients (39%) had undergone previous cardiac surgery and 201 (83%) had chronic atrial fibrillation. Etiology was rheumatic in 51%, myxomatous in 7%, ischemic in 1%, endocarditis in 2%, and due to dysfunction of a previously implanted device in 39%. In total, 115 (47%) patients underwent an associated procedure. Mean follow up was 142+/-24 months (range: 2-181 months); total follow up was 2,627 patient-years. RESULTS: Early mortality was 8.2% (14 patients with low-output syndrome, three with multi-organ failure, one with stroke and two with major bleeding, 2). Late mortality was 45% (3.8%/pt-year) (84 cardiac deaths, 38 being valve-related). Actuarial survival at 5, 10 and 15 years was 69+/-3%, 52+/-3% and 38+/-4%, respectively. Actuarial estimates of freedom from structural valve deterioration (SVD) at 5, 10 and 15 years were 93+/-2%, 64+/-4%, and 25+/-9%; in almost all cases SVD occurred in progressive fashion. At 5, 10 and 15 years, estimates of freedom from thromboembolism were respectively 90+/-2%, 83+/-3% and 83+/-3%, for anticoagulant-related hemorrhage 96+/-1%, 88+/-3% and 88+/-3%, for endocarditis 96+/-1%, 94+/-2% and 94+/-2%, and for reoperation 93+/-2%, 67+/-4% and 54+/-6%. Estimates of freedom from all valve-related mortality at 5, 10 and 15 years were 87+/-2%, 80+/-3% and 75+/-4%. Multivariate analysis (Cox model) showed younger age to be a significant risk factor for reoperation. CONCLUSION: Long-term results with the Xenomedica device implanted in the mitral position appear in line with those achieved for other first-generation bioprostheses. However, incidence of primary tissue failure within 10 years was unsatisfactory. Although sudden dysfunction of the device never occurred, close monitoring of survivors is warranted.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bioprótesis / Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Enfermedades de las Válvulas Cardíacas / Válvula Mitral Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Animals / Female / Humans / Male / Middle aged Idioma: En Revista: J Heart Valve Dis Asunto de la revista: CARDIOLOGIA Año: 2001 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Reino Unido
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bioprótesis / Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Enfermedades de las Válvulas Cardíacas / Válvula Mitral Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Animals / Female / Humans / Male / Middle aged Idioma: En Revista: J Heart Valve Dis Asunto de la revista: CARDIOLOGIA Año: 2001 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Reino Unido