Your browser doesn't support javascript.
loading
Magnetic resonance myocardial first-pass perfusion imaging: parameter optimization for signal response and cardiac coverage.
Bertschinger, K M; Nanz, D; Buechi, M; Luescher, T F; Marincek, B; von Schulthess, G K; Schwitter, J.
Afiliación
  • Bertschinger KM; Institute of Diagnostic Radiology, University Hospital, Zurich, Switzerland.
J Magn Reson Imaging ; 14(5): 556-62, 2001 Nov.
Article en En | MEDLINE | ID: mdl-11747007
Fast imaging techniques allow monitoring of contrast medium (CM) first-pass kinetics in a multislice mode. Employing shorter recovery times improves cardiac coverage during first-pass conditions, but potentially flattens signal response in the myocardium. The aim of this study was therefore to compare in patients with suspected coronary artery disease (CAD) two echo-planar imaging strategies yielding either extended cardiac coverage or optimized myocardial signal response (protocol A/B, six/four slices; preparation pulse, 60 degrees /90 degrees; delay time, 10/120 msec; readout flip angle, 10 degrees /50 degrees; respectively). In phantoms and myocardium of normal volunteers (N= 10) the CM-induced signal increase was 2.5-3 times higher with protocol B (P < 0.005) than with protocol A. For the detection of individually diseased coronary arteries (> or =1 stenosis with > or =50% diameter reduction on quantitative coronary angiography (QCA)), receiver-operator characteristics of protocol B (signal upslope in 32 sectors/heart) yielded a sensitivity/specificity of 82%/73%, which was superior to protocol A (P < 0.05, N= 14). For the overall detection of CAD, the sensitivity/specificity of protocol B was 85%/81%. An adequate signal response in the myocardium is crucial for a reliable detection of perfusion deficits during first-pass conditions. The presented protocol B detects CAD with a sensitivity and specificity similar to scintigraphic techniques.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen Eco-Planar / Enfermedad Coronaria / Miocardio Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2001 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen Eco-Planar / Enfermedad Coronaria / Miocardio Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2001 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Estados Unidos