Limited response to cardiac arrest by police equipped with automated external defibrillators: lack of survival benefit in suburban and rural Indiana--the police as responder automated defibrillation evaluation (PARADE).
Acad Emerg Med
; 8(4): 324-30, 2001 Apr.
Article
en En
| MEDLINE
| ID: mdl-11282666
OBJECTIVE: To assess the out-of-hospital cardiac arrest (OHCA) survival advantage after providing police with automated external defibrillators (AEDs) in rural and suburban Indiana. METHODS: An observational evaluation was conducted in six Indiana counties (population: 464,741) before (retrospective) and after (prospective) training and equipping police with AEDs. The primary outcome evaluated was survival to hospital discharge for all cases of ventricular tachycardia/ventricular fibrillation (VT/VF) OHCA. Other factors evaluated include age, gender, race, arrest location, witnessed arrest, bystander cardiopulmonary resuscitation, response intervals, and survival to discharge for all OHCAs. Results are reported using chi-square, Student's t-test, and logistic regression. RESULTS: Police were equipped with 112 AEDs, increasing total defibrillator capability by 43.2%. During the study period, AED-equipped police responded prior to emergency medical services (EMS) in 26 of 388 cases (6.7%). The time intervals from 911 call-to-scene and 911 call-to-shock were shortened by 1.6 minutes (95% confidence interval [95% CI] = 0.0 to 3.1, p = 0.05) and 4.8 minutes (95% CI = 1.3 to 8.3, p = 0.008), respectively, with police response as compared with EMS response. Survival to hospital discharge for VT/VF OHCA was 15.0% (3/20) in cases in which police responded first and 10.0% (16/160) in cases in which EMS responded first (relative risk [RR] 0.63, 95% CI = 0.17 to 2.39, p = 0.45). Survival to hospital discharge for VT/VF OHCA did not improve from the prestudy period (16/204, 7.8%) to after police AED availability (19/180, 10.6%) (RR 0.72, 95% CI = 0.36 to 1.45, p = 0.38). CONCLUSIONS: Out-of-hospital cardiac arrest survival in suburban and rural Indiana did not improve after police were equipped with AEDs, likely related to poor police response.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Cardioversión Eléctrica
/
Policia
/
Servicios Médicos de Urgencia
/
Paro Cardíaco
Tipo de estudio:
Etiology_studies
/
Evaluation_studies
Límite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
País/Región como asunto:
America do norte
Idioma:
En
Revista:
Acad Emerg Med
Asunto de la revista:
MEDICINA DE EMERGENCIA
Año:
2001
Tipo del documento:
Article
País de afiliación:
Estados Unidos
Pais de publicación:
Estados Unidos