OBJECTIVES: This study evaluated the usefulness of washout rate analysis in adenosine triphosphate(ATP) stress thallium-201 scintigraphy for the diagnosis of vasospastic angina. METHODS: This study included 76 patients with vasospastic angina and 18 normal controls undergoing coronary arteriography. If significant coronary artery stenosis (> or = 50%) was pointed out, the subject was excluded from this study. 111 MBq of thallium-201 was intravenously injected 3 min after ATP loading (0.16 mg/kg/min) was started. Single photon emission computed tomography (SPECT) was performed 10 min and 4 hr after intravenous injection of ATP. The mean washout rate (%) was calculated based on a bull's eye map and was divided into 3 regions, the antero-septal/lateral/inferior regions. The washout rate in each region was calculated. Regional uptake was visually estimated based on the 17 segments of SPECT images. RESULTS: The washout rate in the normal control group was 48.9 +/- 4.1 (mean +/- SD)%. In patients with vasospastic angina, the washout rate in areas with coronary vasospasm was 33.4 +/- 5.5%. This value was significantly lower than in the areas without coronary vasospasm (42.8 +/- 3.6%). The usefulness of washout rate analysis in the diagnosis of vasospastic angina with a cut-off value of less than -2SD from normal washout rate in the 3 regions was examined. A significantly higher diagnostic value was found by washout rate analysis (sensitivity 72.3%, specificity 79.7%, and accuracy 74.6%) compared with visual evaluation of early images (sensitivity 50.3%, specificity 73.9%, and accuracy 57.5%). CONCLUSIONS: The diagnostic value of washout rate analysis was significantly higher (73.1%) compared with visual evaluation of early images (50.3%) in patients with multivessel vasospastic angina.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radioisótopos de Talio / Tomografía Computarizada de Emisión de Fotón Único / Adenosina Trifosfato / Vasoespasmo Coronario / Corazón / Angina de Pecho Tipo de estudio: Diagnostic_studies Límite: Female / Humans / Male / Middle aged Idioma: Ja Revista: J Cardiol Asunto de la revista: CARDIOLOGIA Año: 2000 Tipo del documento: Article Pais de publicación: Países Bajos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radioisótopos de Talio / Tomografía Computarizada de Emisión de Fotón Único / Adenosina Trifosfato / Vasoespasmo Coronario / Corazón / Angina de Pecho Tipo de estudio: Diagnostic_studies Límite: Female / Humans / Male / Middle aged Idioma: Ja Revista: J Cardiol Asunto de la revista: CARDIOLOGIA Año: 2000 Tipo del documento: Article Pais de publicación: Países Bajos