Gas chromatographic method for the determination of toluidines in spiked urine samples.
Jodynis-Liebert, J; Bennasir, H A.
Afiliación
  • Jodynis-Liebert J; Department of Toxicology, Karol Marcinkowski University of Medical Sciences in Poznañ, Poland. liebert@usoms.poznan.pl
J Chromatogr B Biomed Sci Appl ; 738(2): 427-30, 2000 Feb 11.
Article en En | MEDLINE | ID: mdl-10718661
A capillary gas-chromatographic method was developed for the analysis of a mixture of toluidines in urine. The method is based on the extraction of toluidines with toluene and derivatisation with heptafluorobutyric anhydride to form a product for electron capture detection. The procedure gave a linear response at concentrations of 0.02-0.20 microg/ml with sufficient reproducibility. The method is simple, requires little sample pretreatment and is being considered for biomonitoring workers exposed to toluidines.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Toluidinas Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Chromatogr B Biomed Sci Appl Asunto de la revista: QUIMICA CLINICA Año: 2000 Tipo del documento: Article País de afiliación: Polonia Pais de publicación: Países Bajos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Toluidinas Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Chromatogr B Biomed Sci Appl Asunto de la revista: QUIMICA CLINICA Año: 2000 Tipo del documento: Article País de afiliación: Polonia Pais de publicación: Países Bajos